Read these instructions completely and carefully.

Advance Planning

Safety Instructions

The warming drawer may be installed directly into a wall or wall oven cabinetry.

The warming drawer may be installed below a countertop, a single or double oven and side by side using 2 drawers.

When installing warming drawer with a cooktop allow a 2″ minimum from bottom of a cooktop burner box to top of cutout.

Electrical power cord is located on the right

side of the warming drawer. Locate the outlet within reach of the 56″ long power cord in adjacent cabinet, within 42″ of the right side or 16″ from the left side of the cutout.

A recessed receptacle can be installed on the right side of the cutout, 7″ maximum from the back of the cabinet.

Operating Instructions

Grounding the Appliance

IMPORTANT—(Please read carefully)

FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.

Do not use an extension cord or adapter plug with this appliance. Follow National Electrical codes and ordinances.

This warming drawer must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or time delay fuse.

A properly grounded 3-prong receptacle

should be located within reach of the drawer’s 56″ long power cord.

Locate the receptacle in an adjacent cabinet.

—within 42″ of the right side or,

—within 16″ of the left side or

—A recessed receptacle may be located on the right side of the cutout, 7″ maximum from the back of the cabinet. In this location, the excess power cord should be coiled and taped to the right side of the unit.

Recessed receptacle 7max. from rear on right side

Drill 112hole for power cord for left or right side outlet location

IMPORTANT—(Please read carefully)

The power cord of this appliance is equipped with a 3-prong (grounding) plug that mates with a standard 3-prong grounding wall receptacle to minimize the possibility of electric shock. The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded and has the correct polarity.

Where a standard 2-prong wall receptacle is encountered, it is the personal responsibility and obligation of the customer to have it replaced with a properly grounded 3-prong wall receptacle.

Care and Cleaning Installation Instructions Troubleshooting Tips

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.

DO NOT USE AN EXTENSION CORD.

11

Consumer Support

Page 11
Image 11
GE JTD915 owner manual Advance Planning, Grounding the Appliance, IMPORTANT-Please read carefully, Operating Instructions