Installation Instructions
8FOR 31⁄4″ X 10″ RECTANGULAR
DUCTED DISCHARGE INSTALLATIONS
ONLY:
Attach exhaust adaptor/damper over the appropriate knockout opening (for vertical or horizontal, depending on installation) with two exhaust adaptor screws. Make sure damper pivot is nearest to top/back edge of hood. Remove tape from damper flap.
Exhaust adaptor/damper |
|
(vertical discharge position) | Tape |
|
Pivot | Top/back edge | |
(depending on | ||
| ||
installation) | Exhaust adaptor/damper | |
| ||
| (horizontal discharge position) |
9FOR 7″ ROUND VERTICAL DUCTED
DISCHARGE INSTALLATIONS ONLY:
Bend up the duct alignment ears in preparation for later attachment of the 7″ duct.
Attachment ear tabs
10FOR RECESSED-BOTTOM CABINETS
ONLY
Wood shims
(minimum thickness 3/8″)
•If the cabinets have front, side or back trim, make 2 wood shims a minimum of 3/8″ thick and cut to fit the width of the inner recessed cabinet bottom. Attach them to the cabinet bottom recess on both sides. See Step 11 for marking locations.
11