Installation Instructions

11MARK HOLES

Select the vent option that your installation will require and proceed to that section:

A. Outside top exhaust

(Vertical duct–314x 10Rectangular)

Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, electrical wiring and keyhole screw slots.

Hood mounting screws (4)

1034(24hood)

 

1034(24hood)

 

1334(30hood)

 

1334(30hood)

 

1634(36hood)

 

1634(36hood)

 

Cabinet front

 

 

 

 

 

 

 

 

734

 

 

Cabinet Bottom

 

 

514

514

958

334

Vertical duct

114

 

access hole

 

138

12

 

 

 

 

Wood shims

 

 

 

Electrical access hole

Center

 

(in cabinet bottom)

 

(recessed-bottom

 

 

cabinets only–shims

line

 

must be a minimum of

 

3/8thick and cut to fit

 

the width of the inner

 

recessed cabinet bottom)

 

B. Outside top exhaust (Vertical duct–7Round)

Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, electrical wiring and keyhole screw slots.

Hood mounting screws (4)

1034(24hood)

 

1034(24hood)

 

 

 

1334(30hood)

 

1334(30hood)

 

 

 

1634(36hood)

 

1634(36hood)

 

 

 

Cabinet front

 

 

 

 

 

Cabinet

 

734

 

 

 

bottom

8DIA.

 

9

5

8

Access

114

HOLE

 

hole for 7

 

534

 

 

 

round duct

 

 

138

 

 

 

 

 

 

 

Wood shims (recessed-bottom

 

Electrical access

 

 

 

Center

hole (in cabinet bottom)

 

 

cabinets only–shims must be a

 

 

minimum of 3/8thick and cut

line

 

 

 

 

to fit the width of the inner

 

 

 

 

 

recessed cabinet bottom)

 

 

 

 

 

C. Outside rear exhaust

(Horizontal duct–314x 10Rectangular)

Use the diagram or the hood as a template and mark the locations on the cabinet for ductwork, electrical wiring and keyhole screw slots.

Wood shims

(recessed-bottom cabinets only–shims must be a minimum of 3/8thick and cut to fit the width of the inner recessed cabinet bottom)

 

Cabinet front

12114

334

Horizontal duct

 

Cabinet

access hole

 

 

514

514

 

bottom

 

 

 

734

 

1034(24hood)

1034(24hood)

1334(30hood)

1334(30hood)

1634(36hood)

1634(36hood)

Hood mounting screws (4) Center line

Electrical access hole

 

 

 

(in wall)

D. Recirculating (non-vented ductless– JN327 and RN328, and optional on JV247, JV248, JV347, JV348 and JV367 models only)

Use the hood as a template and mark the locations on the cabinet for the electrical wiring and keyhole screw slots.

Since the hood is to be recirculated (not to be vented outside), do not cut out any vent openings in the wall or cabinet bottom.

12CUT HOLES

Cut holes at marked locations for duct and electrical wiring. For the vertical duct, cut out 3/4extra toward the front of the cabinet so you can move the duct freely when installing the hood. It may also ease installation by cutting the hole 1012instead of 10.

13RUN WIRES

Run the electrical wires through the wall or cabinet according to National Electrical Code and applicable local codes.

NOTE: DO NOT turn the power on until installation is complete.

12