Magnetron

Magnetron

WARNING: Prior to servicing the magnetron, be certain the capacitor is discharged. Manually discharge by placing an insulated-handle screwdriver between the diode connection of the capacitor and the oven chassis ground.

To remove the magnetron:

1.Remove the outer cover. (See Outer Cover.)

2.Disconnect wiring to the magnetron.

3.Remove the 2 Phillips-head screws that attach the magnetron to the oven.

DisconnectDisconnect

Disconnect

View From Right Side

Vent Fan Motor Capacitor

The vent fan motor capacitor is located on the top of the oven above the cooling fan.

To remove the vent fan motor capacitor:

1.Remove the outer cover. (See Outer Cover.)

2.Disconnect wiring to the motor capacitor.

3.Remove the Phillips-head screw that attaches the motor capacitor to the oven.

Disconnect

Disconnect

Cooling Fan Motor

The cooling fan and motor are located on the right side of the microwave oven.

To remove the cooling fan and motor:

1.Remove the control panel assembly. (See Control Panel Assembly.)

2.Remove the outer cover. (See Outer Cover.)

3.Disconnect the wiring to the cooling fan motor.

4.Remove the Phillips-head screw from the top, right corner of the microwave.

Disconnect

(Continued Next Page)