GE MDS 05-4558A01 manual Specifications, General, Transmitter, Receiver

Models: MDS 05-4558A01

1 20
Download 20 pages 32.09 Kb
Page 17
Image 17

SPECIFICATIONS

GENERAL

Temperature Range:

 

–40° C to +70° C (–40° F to 158° F)

Humidity:

 

95% at +40° C (104° F); non-condensing

Primary Power:

 

10–30 Vdc

 

 

External Power Supply Options:

48 Vdc; 110–120/210–220 Vac

Typical Current Consumption (assumes 1 Watt RF Output):

 

 

 

 

 

 

 

Mode

DC Power

13.8 Vdc

24 Vdc

 

 

 

 

 

 

 

 

AP Transmit

25 W

 

1.8 A

1.0 A

 

 

 

 

 

 

 

 

AP Receive

8 W

 

579 mA

333 mA

 

 

 

 

 

 

 

 

RM Transmit

25W

 

1.8 A

1.0 A

 

 

 

 

 

 

 

 

RM Receive

6.5W

 

471 mA

270 mA

 

 

 

 

Size (without mtg. hardware):

5.72 H x 20 W x 12.38 D cm

 

 

 

(2.25 H x 7.88 W x 4.88 D in.)

Mounting Options:

 

Flat surface brackets, DIN rail, 19” rack

Weight:

 

1kg / 2.2 lb.

 

 

Case:

 

Die Cast Aluminum

 

 

RADIO CHARACTERISTICS

 

 

 

 

GENERAL:

 

 

 

 

 

Frequency Band:

 

Mercury 900: 902–928 MHz

 

 

 

Industrial, Scientific & Medical (ISM) Band

 

 

 

Mercury 3650: 3650–3700 MHz

 

 

 

FCC Registered Band

 

 

TRANSMITTER:

 

 

 

 

 

RF Output @ connector:

 

Mercury 900: –30 to +30 dBm

 

 

 

Mercury 3650: 0 to 20 dBm

 

 

 

Increments of 1.0 dB, set by user

Duty Cycle:

 

Continuous

 

 

Output Impedance:

 

50 Ohms

 

 

RECEIVER:

 

 

 

 

 

Type:

 

Double conversion superheterodyne

Sensitivity and Data Rate:

 

Dependent on modulation and bandwidth.

 

 

 

See Reference Manual Specifications.

14

MDS Mercury Series Startup Guide

05-4558A01, Rev. C

Page 17
Image 17