Installation Instructions

IMPORTANT SAFETY INSTRUCTIONS

For Your Safety

WARNING: For personal safety, remove house fuse or open circuit

breaker before beginning installation. Failure to do so could result in serious injury or death.

All rough-in and spacing dimensions must be met for safe use of your range.

To reduce the risk of burns or fire when reaching over hot surface elements, cabinet storage space above the cooktop should be avoided. If cabinet storage space is to be provided above the cooktop, the risk can be reduced by installing a range hood that sticks out at least 5” beyond the front of the cabinets.

Cabinets installed above the cooktop must be no deeper than 13”.

Be sure your appliance is properly installed and grounded by a qualified technician.

Electrical

Requirements

This appliance must be supplied with the proper voltage and frequency, and connected to an individual, properly grounded branch circuit, protected by a circuit breaker or fuse having amperage as noted on rating plate. (Rating Plate is located behind the oven door on the range.)

We recommend you have the electrical wiring and hookup of your range connected by a qualified electrician. After installation, have the electrician show you where your main range disconnect is located.

Check with your local utilities for electrical codes which apply in your area. Failure to wire your range according to governing codes could result in a hazardous condition. If there are no local codes, your range must be wired and fused to meet the requirements of the National Electrical Code, ANSI/NFPA No. 70–Latest Edition. You can get a copy by writing:

National Fire Protection Association

Batterymarch Park

Quincy, MA 02269

Effective January 1, 1996, the National Electrical Code requires that new, but not existing, construction utilize a four-conductor connection to an electric range. When installing an electric range in new construction, a mobile home, recreational vehicle or an area where local codes prohibit grounding through the neutral conductor, follow the instructions in the section on NEW CONSTRUCTION AND FOUR-

CONDUCTOR BRANCH CIRCUIT CONNECTION.

You must use a three-wire, single-phase A.C. 208Y/120 Volt or 240/120 Volt, 60 hertz electrical system. If you connect to aluminum wiring, properly installed connectors approved for use with aluminum wiring must be used.

Rating Plate

Location

2

Page 2
Image 2
GE PD900, PD968 installation instructions Installation Instructions

PD968, PD900 specifications

The GE PD900 and PD968 models represent a significant advancement in the field of generator technology, offering exceptional performance and reliability for various applications within industrial and commercial sectors. Both models are designed to address the increasing demand for efficient power generation while ensuring minimal environmental impact.

One of the standout features of the GE PD900 and PD968 is their advanced design that enhances fuel efficiency. Equipped with cutting-edge technology, these generators utilize high-efficiency combustion systems that optimize fuel consumption, ultimately reducing operational costs for businesses. The PD900 delivers an impressive output of up to 900 kVA, while the PD968 takes it a step further with a capacity of 968 kVA, making them suitable for both medium and large-scale power requirements.

Incorporating the latest in generator control technology, the PD900 and PD968 models feature a sophisticated control panel that provides real-time monitoring and management of the generator’s performance. This allows operators to easily track critical metrics such as voltage, frequency, and load, facilitating timely maintenance and reducing the risk of unexpected failures.

These generators are also designed with a focus on durability and ease of operation. The robust construction and high-quality materials ensure longevity and reliability, even in the most demanding environments. Furthermore, the PD900 and PD968 come with an array of safety features, including automatic shut-off systems and overload protection, enhancing operational integrity.

An important characteristic of the GE PD900 and PD968 generators is their versatility. They can be tailored to meet specific power needs, whether for temporary usage in construction sites, as backup power for hospitals, or for continuous operation in manufacturing facilities. This adaptability makes them a preferred choice across multiple industries.

Moreover, both models comply with stringent environmental regulations, featuring lower emissions and noise levels compared to traditional generators. This commitment to sustainability not only helps organizations meet their environmental goals but also fosters a more pleasant working environment.

In summary, the GE PD900 and PD968 generators are engineered to deliver high performance, reliability, and efficiency. With their advanced technologies, superior features, and commitment to sustainability, they stand out as exemplary solutions for modern power generation needs. Businesses looking for dependable and efficient power sources will find that these models meet and exceed industry standards.