Zoneline® chassis nomenclature | Zoneline warranty* |
The Zoneline® chassis is identified by a model number defining the type of unit, cooling capacity, electrical information and optional features included on the unit. When specifying or ordering the Zoneline chassis, use of this nomenclature will assure receiving the correct unit.
A | Z | 5 |
| 8 |
| H | 1 | 2 | D | A | D | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Zoneline |
| Chassis series |
|
|
| Nominal cooling capacity |
|
| Universal |
|
|
| |||||||||
packaged |
| 29=deluxe line cool/ |
| 07=7,000 BTUH cooling |
|
| power connection |
|
| ||||||||||||
terminal |
| electric heat |
|
|
| 09=9,000 BTUH cooling |
|
|
|
|
|
|
| ||||||||
chassis |
| 39=deluxe line heat pump |
| 12=12,000 BTUH cooling |
|
| Special Features |
|
| ||||||||||||
|
|
|
| 58=premium line |
| 15=15,000 BTUH cooling |
|
| B=base unit |
|
| ||||||||||
|
|
|
| heat pump |
|
|
|
|
|
|
|
|
|
| C=corrosion treated | ||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
| Voltage/Phase/ |
|
| D=internal |
|
| |||||
|
|
|
| Unit type |
|
|
|
| Frequency |
|
|
|
|
| condensate |
|
| ||||
|
|
|
| E=cooling with electric |
|
| D=230/208 Volt, single |
|
|
| removal (ICR) |
|
| ||||||||
|
|
|
| resistance heat |
|
| phase, 60 Hz |
|
|
| system (heat |
|
| ||||||||
|
|
|
| H=heat pump with electric |
|
| E=265 Volt, single phase, |
|
|
| pump models |
|
| ||||||||
|
|
|
| resistance heat |
|
| 60 Hz |
|
|
|
|
| only) (not for |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| coastal areas) |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| P=Dry Air 25 |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
What is covered
Limited
For one year from the date of the original purchase, GE will repair or replace any part of the air conditioner which fails due to a defect in materials or workmanship. During this limited
Limited
For five years from the date of the original purchase, GE will repair or replace the Sealed Refrigerating System if any part of the Sealed Refrigerating System (the compressor, condenser, evaporator, and all connecting tubing) should fail due to a defect in materials or workmanship. During this limited
the defective part.
Limited second through fifth year parts warranty
From the second through the fifth year from the date of the original purchase, GE will replace the Fan Motors, Switches, Thermostat, Heater, Heater Protectors, Compressor Overload, Solenoids, Circuit Boards, Auxiliary Controls, Thermistors, Freeze Sentinel, Frost Controls, ICR Pump, Capacitors, Varistors and Indoor Blower Bearing, if any of these parts should fail due to a defect in materials or workmanship. During this additional
*See written warranty for details
|
|
|
|
|
|
|
|
|
| T |
|
|
| |
|
|
|
|
|
|
|
| TIFIED | O ARI | AS |
|
| ||
|
|
|
|
| ER |
|
|
|
|
| ||||
|
|
|
|
| C |
|
|
|
|
| C | M | ||
|
|
|
|
| R |
|
|
|
|
|
|
|
| |
|
|
|
|
| E |
|
|
|
|
|
|
| O | |
Listed by | U |
| U | R |
|
| D |
| T |
|
| P | ||
| PA |
|
|
| L | W | ||||||||
|
|
|
|
|
|
|
|
| L | |||||
| C | T |
|
|
| K | A | G |
|
|
| M |
| I |
|
|
|
|
|
|
|
|
| N | N | ||||
| FA |
|
|
| C |
|
|
|
|
|
| I |
|
|
Underwriters |
|
|
|
|
|
|
| R |
| A | G | |||
N |
|
|
|
|
|
|
|
|
|
|
| I | ||
| A |
|
|
|
|
|
|
|
|
|
|
|
| T |
| M |
|
|
|
|
|
|
|
|
|
|
|
| H |
Laboratories. |
|
|
|
|
|
| AI |
|
|
| 1 |
| ||
|
|
|
|
|
|
|
|
| S |
|
| |||
|
|
|
|
|
|
|
| R- |
| ER |
|
|
| |
|
|
|
|
| A |
|
|
| CONDITION |
| 0 | |||
|
|
|
|
|
|
|
|
|
|
| 3 | |||
|
|
|
|
| RI | S |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| D |
|
| ||
|
|
|
|
|
|
|
|
| TANDAR |
|
|
|
For detailed information on operating specifications, installation data and accessories, see the GE Zoneline Architects and Engineers Design Data Manual.
|
|
|
|
|
| TIFIED | T |
|
|
| ||
|
|
|
|
|
| O ARI | AS |
|
| |||
|
|
| ER |
|
|
|
|
| ||||
|
|
| C |
|
|
|
|
| C | M | ||
|
|
| R |
|
|
|
|
|
|
|
| |
|
|
| E |
|
|
|
|
|
|
| O | |
|
| R |
|
| D | T |
|
| P | |||
|
|
|
|
|
|
| L | |||||
| T | U |
|
|
| E |
|
| ER |
| Y | |
C |
|
| K | A | G |
|
|
| M |
| I | |
|
|
|
|
|
|
| N | N | ||||
A |
|
| C |
|
|
|
|
|
| I |
|
|
|
|
|
|
|
|
|
| A | G | |||
F |
|
| A |
|
|
|
|
|
| L | W | |
U |
|
| P |
|
|
|
|
|
|
|
| |
N |
|
|
|
|
|
|
|
|
|
|
| I |
A |
|
|
|
|
|
|
|
|
|
|
| T |
M |
|
|
|
|
|
|
|
| R |
|
| H |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| A |
|
|
| HEAT | PUMPS |
| 0 | ||
|
|
|
|
|
|
|
|
| 3 | |||
|
|
| RI |
|
|
|
|
|
| |||
|
|
|
|
|
| S |
|
|
| 8 |
| |
|
|
|
|
|
|
|
| D |
|
| ||
|
|
|
|
|
|
| TANDAR |
|
|
|
A century of quality and innovation
For more than a century, GE has been committed to producing innovative products that change the way people live. The result of thorough research and rigorous testing, GE appliances are designed for years of dependable performance.
Today, the GE tradition of quality and innovation continues.
GE Consumer & Industrial
Appliances
General Electric Company Louisville, KY 40225
ge.com
zoneline.com
For GE appliance service in the US, call
GE has a policy of continuous improvement of its products and reserves the right to change materials and specifications without notice.
© 2008 GE Company |
|
Pub. No. | PC51902 |