GE PDW9880J manual Premium models, series, Wall sleeve dimensions, Electrical connection

Models: PDW9880J

1 12
Download 12 pages 29.48 Kb
Page 9
Image 9
Premium models

Premium models

5800 series

Highly featured microcomputer controls

ge.com

Cross-flow blower Quiet blower reduces annoying “Air rush” noise.

Reversible louver (not shown)

May be reversed to provide an air discharge angle of 40 or 50 degrees off vertical with the removal of six screws.

3 position vent control (not shown)

Opens vent. Provides up to 70 cfm of outdoor air. The closed position saves energy by recirculating conditioned room air.

Solid state thermostat control Provides better room temperature control vs. electromechanical temperature control device.

Freeze SentinelProvides automatic protection against freezing by switching the unit to heat should the temperature of an unoccupied room drop to 41°F.

Heat Sentinel Provides automatic protection against overheating by switching on the unit to cool should the temperature of

an unoccupied room reach 85°F.

Room occupancy sensor compatible Ready for connection to room occupancy sensor system.

Weather-protected electrical components On inside of barrier.

Auto frost control monitor

A special sensor monitors the roomside coil to prevent efficiency-robbing accumulation of frost during cooling cycle.

Electronic temperature limiting Preset cooling and heating limits with 7 independent cooling and 7 heating limits—saves energy by preventing over-cooling or over-heating of rooms.

“Smartfan”

fan cycle selection Select fan cycle or fan continuous independently for heating and cooling.

Two fan motors (not visible) Separate motors for indoor and outdoor fans to assure quiet operation.

Touch pad controls With electronic control temperature display. Gives the user finer control over the temperature.

 

 

Reverse cycle defrost

 

 

(not shown)

 

 

Solid state sensor

 

 

monitors frost build-up

 

 

on outdoor coil. When

 

 

frost is detected, the

 

 

refrigerant flow is reversed

 

 

to melt frost build-up.

 

 

When completed, the

 

 

refrigerant is reversed

 

 

to the normal energy

 

 

saving heat pump

 

 

operation for additional

Universal power cord

Rotary compressor

heat pump operating hours.

Central desk

Flexibility of heat

With fewer moving

applications. Each

parts than reciprocating

control compatible

premium line Zoneline

models for quiet,

Ability to turn the unit

contains a bank of

reliable operation.

“on” or “off” from a

3 heaters.

Easy-access filter

remote location.

Microcomputer controls

Remote control

(not shown)

Electronic components

Two upfront filters

compatible

for fast response and

are part of roomside

Ability to be controlled

accuracy.

cabinet for easy access

by a wall-mounted

 

and maintenance.

thermostat with high

 

 

or low fan speed.

Wall sleeve dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

Heavy-gauge galvanized

A

 

 

 

 

 

 

 

 

steel with a baked enamel

 

 

 

 

 

finish for outstanding

 

 

 

 

 

protection and appearance.

 

 

 

 

 

RAB71A wall sleeve

 

 

 

 

 

 

 

 

 

 

Heavy-gauge galvanized steel, with insulation.

 

 

B

 

 

A-42", B-13 3/4", C-16"

 

 

 

 

 

 

 

RAB77A4 wall sleeve (shown above)

Molded SMC fiberglass-reinforced polyester compound. A-42 1/8", B-13 7/8", C-16 1/4"

Wall opening dimensions

Add 1/4" to A and C dimensions for all cutout sizes. RAB71 16 1/4" min. H. x 42 1/4" min. W.

RAB71 available in 16", 24", 28" and 31" depths. RAB77A4 16 1/2" min. H. x 42 3/8" min. W.

Electrical connection

230/208 volt units may be plugged into a receptacle. 265 volt units are provided

with a junction box and require direct

C connection. (NEC Requires 265V Direct

Connection.) See Architects and Engineers Design Data Manual for electrical connection information including use of sub-base for direct-connected units. Installation

must comply with local electrical codes and regulations.

Ducted applications

2900 and 3900 series can be used with ductwork to heat or cool more than one room. RAK6052 Duct Adapter is applied to top of case over air discharge. RAK601 Duct Extension is applied to right or left of adapter.

Locally fabricated ductwork may be added to extend to maximum recommended distance of 15 feet.

For additional information on ducted applications, including special adapters for replacement units, refer to Architects and Engineers Design Data Manual.

Page 9
Image 9
GE PDW9880J Premium models, series, Wall sleeve dimensions, Electrical connection, Ducted applications, RAB71A wall sleeve