Premium models
5800 series
Highly featured microcomputer controls
ge.com
Reversible louver (not shown)
May be reversed to provide an air discharge angle of 40 or 50 degrees off vertical with the removal of six screws.
3 position vent control (not shown)
Opens vent. Provides up to 70 cfm of outdoor air. The closed position saves energy by recirculating conditioned room air.
Solid state thermostat control Provides better room temperature control vs. electromechanical temperature control device.
Freeze Sentinel™ Provides automatic protection against freezing by switching the unit to heat should the temperature of an unoccupied room drop to 41°F.
Heat Sentinel Provides automatic protection against overheating by switching on the unit to cool should the temperature of
an unoccupied room reach 85°F.
Room occupancy sensor compatible Ready for connection to room occupancy sensor system.
Auto frost control monitor
A special sensor monitors the roomside coil to prevent
Electronic temperature limiting Preset cooling and heating limits with 7 independent cooling and 7 heating
“Smartfan”
fan cycle selection Select fan cycle or fan continuous independently for heating and cooling.
Two fan motors (not visible) Separate motors for indoor and outdoor fans to assure quiet operation.
Touch pad controls With electronic control temperature display. Gives the user finer control over the temperature.
|
| Reverse cycle defrost | |
|
| (not shown) | |
|
| Solid state sensor | |
|
| monitors frost | |
|
| on outdoor coil. When | |
|
| frost is detected, the | |
|
| refrigerant flow is reversed | |
|
| to melt frost | |
|
| When completed, the | |
|
| refrigerant is reversed | |
|
| to the normal energy | |
|
| saving heat pump | |
|
| operation for additional | |
Universal power cord | Rotary compressor | heat pump operating hours. | |
Central desk | |||
Flexibility of heat | With fewer moving | ||
applications. Each | parts than reciprocating | control compatible | |
premium line Zoneline | models for quiet, | Ability to turn the unit | |
contains a bank of | reliable operation. | “on” or “off” from a | |
3 heaters. | remote location. | ||
Microcomputer controls | Remote control | ||
(not shown) | |||
Electronic components | Two upfront filters | compatible | |
for fast response and | are part of roomside | Ability to be controlled | |
accuracy. | cabinet for easy access | by a | |
| and maintenance. | thermostat with high | |
|
| or low fan speed. |
Wall sleeve dimensions |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
A |
|
|
| ||||
|
|
|
|
| |||
steel with a baked enamel |
|
|
|
|
| ||
finish for outstanding |
|
|
|
|
| ||
protection and appearance. |
|
|
|
|
| ||
RAB71A wall sleeve |
|
|
|
|
| ||
|
|
|
|
| |||
|
| B | |||||
|
| ||||||
|
| ||||||
|
|
|
|
|
RAB77A4 wall sleeve (shown above)
Molded SMC
Wall opening dimensions
Add 1/4" to A and C dimensions for all cutout sizes. RAB71 16 1/4" min. H. x 42 1/4" min. W.
RAB71 available in 16", 24", 28" and 31" depths. RAB77A4 16 1/2" min. H. x 42 3/8" min. W.
Electrical connection
230/208 volt units may be plugged into a receptacle. 265 volt units are provided
with a junction box and require direct
C connection. (NEC Requires 265V Direct
Connection.) See Architects and Engineers Design Data Manual for electrical connection information including use of
must comply with local electrical codes and regulations.
Ducted applications
2900 and 3900 series can be used with ductwork to heat or cool more than one room. RAK6052 Duct Adapter is applied to top of case over air discharge. RAK601 Duct Extension is applied to right or left of adapter.
Locally fabricated ductwork may be added to extend to maximum recommended distance of 15 feet.
For additional information on ducted applications, including special adapters for replacement units, refer to Architects and Engineers Design Data Manual.