Step-by-step installation instructions.

4A. CONNECTING A RIGID VALVE DRAIN TUBE

To adapt a copper drain tube to the softener, use a hacksaw to cut the barbed end from the drain fitting as shown in Fig. 4A. Rotate the drain fitting so the cutting

blade clears the valve housing to prevent damage to valve. Buy a compression fitting (1/4″ female pipe thread x 1/2″ O.D. tube) and needed tubing from your local hardware store.

5. INSTALL THE BRINE TANK OVERFLOW FITTINGS AND HOSE

Insert the rubber grommet into the 3/4″ diameter hole in the brine tank sidewall as shown in Fig. 5.

Push the end of the hose adapter elbow into the grommet as shown in Fig. 5.

Attach a length of hose (use remaining hose from Step 4) to the hose adapter elbow. Use a hose clamp to hold it in place.

Locate the other end of the hose at the drain point. DO NOT ELEVATE this hose higher than the elbow on the brine tank.

IMPORTANT: DO NOT TEE OVERFLOW HOSE TO VALVE DRAIN HOSE.

NOTE: This drain is for safety only. If the cabinet (brine tank) should over-fill with water, the excess is carried to the drain.

6. INSTALL GROUNDING CLAMPS AND WIRE

DANGER: Failure to properly attach ground wire could result in electrical shock.

If plumbing is metal, to maintain electrical ground continuity in the house cold water piping, install the included ground clamps as shown in Fig. 6. Be sure the pipes are clean under the clamps to assure good contact.

7.FLUSH PIPES, EXPEL AIR FROM SOFTENER, AND TEST YOUR INSTALLATION FOR WATER LEAKS:

Fig. 4A

Clip

Cut barbs from drain fitting

Fig. 5

Grommet

1/4NPT threads

1/2O.D.

Barbs copper tube (not furnished)

Compression fitting, 1/4NPT X 1/2O.D. tube (not furnished)

Hose adapter

Hose clamp

Do not connect to valve drain hose.

CAUTION: To avoid water or air pressure damage to softener inner parts, be sure to do the following steps in exact order.

A. Fully open 2 cold soft water faucets nearby the softener.

Overflow drain hose

B. Place bypass valve in “bypass” position by pushing the stem inward.

C. Fully open the house main water pipe shutoff valve. Observe a steady flow from both faucets opened in step A, above.

Fig. 6

To sewer drain

D. Place bypass valve in the “service” position EXACTLY as follows. KEEP SOFT

To valve inlet

WATER FAUCETS OPEN.

 

SLOWLY pull or slide the valve stem (out) toward “service,”pausing several

Clamp (2)

times to allow the softener to pressurize slowly.

 

E. After about 3 minutes, open a HOT water faucet for 1 minute, or until all air

Ground

is expelled, then close. NOTE: If water appears cloudy or has salty taste,

allow to run for several more minutes, or until clear.

wire

F. Close all water faucets.

 

G. Check your plumbing work for leaks and fix right away if any are found.

 

Be sure to observe previous caution notes.

From valve outlet

 

H. Turn on the gas or electric supply to the water heater. Light the pilot, if applicable.

8. ADD WATER AND SALT TO THE BRINE TANK:

Lift the cabinet (brine tank) cover. Add about 3 gallons of water into the tank. Do not add into the brinewell.

Fill tank with NUGGET, PELLET or coarse SOLAR water softener salt with a purity of 99.5% or higher. Do not use rock, block, granulated, and ice cream-making salts, or salt with iron-removing additives (except for Diamond Crystal® Red•Out® brand salt). Salt storage capacity is approximately 200 lbs. Keep the salt hole cover in place on the softener unless servicing the unit or refilling with salt.

NOTE: If the softener is installed in a humid basement or other damp area, it is better to fill the tank with less salt, more frequently. Eighty to 100 lbs. of salt will last for several months, depending on water hardness, family size and water softening system model.

9. CONNECT TO ELECTRICAL POWER:

If transformer wiring is not visible at the back of the control head, remove control cover. DO NOT PULL ON OR DISCONNECT WIRING. Locate the long wire with “U” shaped connectors on one end. Route this wire through the rear of the control housing. Replace the control cover.

Fasten the 2 power cable lugs (“U” shaped connectors) to the 2 screws on the transformer, and tighten the screws. Then, plug the transformer into the electrical outlet.

The softener works on 24 volt-60Hz electric power. The included transformer changes standard 120 volt AC house power to

24 volts. Plug the transformer into a 120 volt outlet only. Be sure the outlet is always live so it can not be switched off by mistake.

10. PROGRAM THE CONTROL:

8See Programming the Control section.

Page 8
Image 8
GE PNSF39Z01 owner manual 4A. Connecting a Rigid Valve Drain Tube

PNSF39Z01 specifications

The GE PNSF39Z01 is a top-of-the-line smart refrigerator that seamlessly combines advanced technology with energy efficiency, providing an elevated user experience in modern kitchens. Designed by General Electric, a leader in home appliance innovation, this refrigerator boasts an array of features aimed at maximizing convenience and functionality.

One of the standout characteristics of the PNSF39Z01 is its spacious interior, providing ample storage with adjustable shelving and humidity-controlled drawers. This flexibility allows users to customize their storage space according to their needs, catering to varying sizes and types of food items. The refrigerator also features a dedicated freezer section, ensuring that frozen foods are easily accessible and well-organized.

The PNSF39Z01 incorporates GE's advanced cooling technology, which includes a multi-air flow system. This system ensures consistent temperatures throughout the refrigerator, maintaining optimal freshness for perishables. Additionally, the refrigerator is equipped with LED lighting, which not only enhances visibility but also consumes less energy compared to traditional bulbs.

One of the key technologies in this model is the built-in Wi-Fi connectivity. This allows users to control and monitor their refrigerator remotely through a smartphone app, receiving alerts for door ajar situations or filter replacements. The integration of smart technology extends to voice control compatibility with platforms like Amazon Alexa and Google Assistant, allowing hands-free management of settings.

To enhance the water and ice dispensing experience, the PNSF39Z01 features a filtered water dispenser and an advanced ice-making system. The refrigerator includes a reverse osmosis filtration system that ensures clean, great-tasting water is always available. The ice maker produces both crushed and cubed ice, catering to various beverage needs.

Energy efficiency is another hallmark of the GE PNSF39Z01. It meets or exceeds Energy Star standards, significantly reducing electricity consumption while maintaining impeccable performance. This not only benefits the environment but also helps consumers save on energy bills.

Furthermore, the refrigerator's sleek design is complemented by a fingerprint-resistant stainless steel finish, making it easy to maintain. The modern aesthetic integrates well with a variety of kitchen styles, ensuring that it not only functions exceptionally but also looks stylish.

In conclusion, the GE PNSF39Z01 refrigerator stands out for its impressive features, including advanced cooling technologies, smart home connectivity, water and ice dispensers, and energy efficiency. It is a versatile appliance that enhances everyday kitchen tasks and elevates the overall culinary experience.