GE PSI23NCPCC Collar Trim Installation, Typical Installation, Specification Created 2/03

Models: PSI23NCPCC PSI23NCPBB PSI23NCP PSI23NCPWW

1 5
Download 5 pages 23.4 Kb
Page 3
Image 3
Collar Trim Installation

TM

PSI23NCP – GE Profile Arctica22.6 Cu. Ft. CustomStyleSide-by-Side Refrigerator

Collar Trim Installation

An enclosure is required to match up to the trim, see Typical Installation. To obtain the most integrated look, the cabinet or soffit above the refrigerator should extend out to the same depth as the side panels. The refrigerator opening must have minimum dimensions of 70-1/4" high x 36-1/8" wide x 24-1/2" deep as shown at right. If there is an overhead cabinet, allow 1" for cabinet door clearance with the top trim piece so the cabinet doors can be opened without hitting the top trim. If 1/2" side panels are used, then side trim and panel will be even. If 3/4" side panels are used, then some of the side panel will extend beyond the trim and must be finished.

1/2" minimum

3/4" Cabinet

RefrigeratorSide Panel

Case

Typical Installation 1/2" Cabinet

Side Panel

Magnetic

Tape

Door Gasket

Side Trim

Side trim must be installed flush with the gasket contact surface on the case.

Typical Installation

Shaded areas represent front surfaces of

side panels and overhead cabinet or soffit that contacts trim.

Specification Created 2/03

70-1/4"*

24-1/2"*

Manual background 36-1/8"Manual backgroundManual background

*The rough-in dimension of 70-1/4" is minimum and is measured from the finished floor to top of opening (or the underside of the overhead cabinets). For Models with Trim Kit: If frameless style cabinets are planned for above the refrigerator, you may need to consider adding a maximum of 1/4" (70-1/2") to height of opening to allow additional clearance between cabinet doors and top of refrigerator trim when cabinet doors are in open position.

Total volume and shelf

 

 

 

 

area are calculated by the

 

Listed by

 

 

Association of Home

 

Underwriters

 

R

 

 

 

Appliance Manufacturers’

R

Laboratories

 

 

standards.

 

 

 

 

Cabinet

Overhead Manual background Door

Cabinet Manual background

1"

Case

Top Trim

IMPORTANT: Before finalizing specifications for your GE Profile CustomStyle Refrigerator, please NOTE:

A minimum of 36-1/8" is required for refrigerator installation with collar

Be sure to allow for 1/2" or 3/4" side panels in addition to the 36-1/8" minimum

For answers to your Monogram,® GE Profileor GE appliance questions, visit our website at GEAppliances.com or call

GE Answer Center® service, 800.626.2000.

Page 3
Image 3