GE PVIG940 WALL INSTALLATION - Continued, Installation Instructions, Electrical connection

Models: PVWS936 PVIG940 PVWG936 PVWS930 PVWT936

1 24
Download 24 pages 5.87 Kb
Page 13
Image 13
WALL INSTALLATION - Continued

Installation Instructions

WALL INSTALLATION - Continued

13.Model PVWG936:

Fix the 2 supplied brackets on the rear side of the motor housing with 4 screws each.

Lower Support Bracket

Ø3.5 x 9.5

14.Hang hood with the 2 mounting hooks (screws).

WARNING

Excessive Weight Hazard - Use two or more people to move and install range hood. Failure to do so can result in back or other injury.

15.Hang hood with the 2 mounting hooks (screws).Level the appliance, using a carpenters level across bottom of hood and (models PVWS930/936 and PVWT936 only) with leveling screws in mounting hooks.

16.Secure hood with 2 screws on top and (models PVWS930/936 and PVWT936 only) 2 screws on bottom.

Models PVWS930/936 and PVWT936

A. Centerline on Wall

B. Mounting Hooks

C.Mounting Screws

D.Leveling Screws

Ø 6 x 80

Model PVWG936

Ø 6 x 80

17.Install the transition at the top of the hood in case it has been removed.

Ø 3.5 x 9.5

Models PVWS930/936 and

PVWT936

Ø 3.5 x 9.5

Model PVWG936

18.Connect ducting to transition. Seal with duct tape.

Do not use duct smaller than the transition.

19.Electrical connection

WARNING

Electrical Shock Hazard
Turn off power circuit at the service panel before wiring this unit.
120 VAC, 15 or 20 Amp circuit required.

ELECTRICAL GROUNDING INSTRUCTIONS

THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WITH 3 WIRES, ONE OF WHICH (GREEN/YELLOW) SERVES TO GROUND THE APPLIANCE. TO PROTECT YOU AGAINST ELECTRIC SHOCK, THE GREEN AND YELLOW WIRE MUST BE CONNECTED TO THE GROUNDING WIRE IN YOUR HOME ELECTRICAL SYSTEM, AND IT MUST UNDER NO CIRCUMSTANCES BE CUT OR REMOVED.

Failure to do so can result in death or electrical shock.

Remove the knockout and the Junction box cover and install the conduit connector (cUL listed) in junction box.

1 Ft = 0.3 m 1” = 2.5 cm

1 3

Page 13
Image 13
GE PVIG940, PVWT936, PVWS930 WALL INSTALLATION - Continued, Installation Instructions, Electrical connection, Model PVWG936