S P E C I A L F E A T U R E S

POPCORN

The POPCORN setting automatically provides the correct cooking time for most brands of microwave popcorn. You may wish to try several and choose your favorite. Pop only one bag at a time. Unfold bag and place in oven according to directions.

Suppose you want to pop a 3.5 oz bag (regular) of popcorn.

 

P R O C E D U R E

D I S P L A Y

 

 

 

 

 

 

POPCORN

 

reg

 

 

 

 

 

 

Touch POPCORN once.

The oven starts automatically.

Touch POPCORN once for 3.5 oz bag (regular).

Touch POPCORN twice within 2 seconds for 2.85 -

3.5oz bag (light regular).

Touch POPCORN three times within 2 seconds for

1.5or 1.75 oz bag (snack).

NOTE:

To use POPCORN pad, touch within 3 minutes after cooking, opening and closing the door or touching the STOP/CLEAR pad.

REHEAT

REHEAT automatically computes the correct warming time and microwave power level for foods shown in the chart below.

• Suppose you want to reheat 3 cups of soup.

 

 

P R O C E D U R E

D I S P L A Y

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REHEAT

 

FOOD

 

 

Touch REHEAT once.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

2

 

 

 

 

 

 

 

 

2

 

 

Select desired

Reheat

 

 

 

setting. (Ex: touch number

 

 

 

1

 

 

pad 2 to select 1 cup of

CUPS

 

 

 

 

 

 

 

 

 

 

 

 

soup.

 

 

 

 

 

 

REHEAT CHART

3

 

 

3

 

2

 

CUPS

 

 

 

 

 

 

 

 

 

 

Repeat touching same number pad 2 to increase quantity to 3 cups. (Ex: touch 2 two more times for 3 cups or hold down until the desired quantity appears.)

4

START

Touch START pad.

NOTE:

1.To reheat different foods or foods above or below the quantity allowed on the REHEAT CHART, use manual operation.

2.Reheat can be programmed with More or Less Time Adjustment. See page 16.

 

F O O D

A M O U N T

P R O C E D U R E

 

1. Casserole

1-6 cups*

Use this setting to reheat refrigerated, canned or homemade pasta with sauce

 

 

1-8 cups**

or other cooked casserole. For room temperature pasta or casserole, use Less

 

 

 

option (see page 16). For pasta without sauce double the quantity per setting.

 

 

 

For example, measure 2 cups of cooked noodles and program for 1 cup. Cover

 

 

 

with lid or plastic wrap. After cooking, let stand, covered, 2 to 3 minutes.

 

2. Soup

1-6 cups*

Place in bowl or casserole. Cover with lid or plastic wrap. At end, stir, re-cover

 

 

1-8 cups**

and let stand 1 to 3 minutes.

 

3. Pizza

1-6 slices

Use this setting to reheat refrigerated leftover pizza. One slice is approximately

 

 

 

1/8th of a 12 inch pizza or 1/12th of a 16 inch pizza. Place on paper towel.

NOTE: The symbol * is for model numbers R-404F and R-401F only.

The symbol ** is for model numbers R-508F and R-501F only.

11

Page 13
Image 13
GE R-404F, R-501F, R-401F, R-508F warranty E C I a L F E a T U R E S, Popcorn, Reheat Chart, Soup

R-508F, R-401F, R-404F, R-501F specifications

The GE R-501F, R-404F, R-401F, and R-508F are refrigerants specifically designed for various industrial and commercial applications. Each refrigerant possesses unique characteristics that cater to specific refrigeration needs, and they are widely used in systems ranging from refrigeration units to air conditioning systems.

The GE R-501F is noted for its efficiency in medium and low-temperature systems. It has a low global warming potential compared to some traditional refrigerants, making it a more environmentally friendly option. Its thermodynamic properties allow for improved energy savings and reduced operational costs. The R-501F is particularly effective in commercial refrigeration, such as display cases and walk-in coolers, due to its capacity to maintain low temperatures effectively.

R-404F, on the other hand, is a blend of hydrofluorocarbon (HFC) refrigerants that replace R-404A and is designed to offer better energy efficiency and reduced environmental impact. Its composition results in low GWP and excellent performance across a wide range of operating temperatures. R-404F is widely utilized in transport refrigeration, commercial freezers, and HVAC systems. The refrigerant is known for its stable performance and compatibility with various lubricants, making it an attractive option for many applications.

The GE R-401F is another refrigerant designed for low-temperature applications, especially in food refrigeration and commercial cooling. It is formulated to have a lower environmental impact with a balanced thermodynamic performance. R-401F shows minimal glide, which reduces the complexities in refrigerant charge management and enhances system efficiency throughout its lifecycle.

R-508F is specially formulated for ultra-low temperature applications. It is a blend usually used in cascade refrigeration systems where extremely low temperatures are required, such as deep freeze storage and certain laboratory applications. R-508F has excellent thermodynamic properties, including a low boiling point and high efficiency, allowing it to operate effectively even under extremely low temperature conditions.

Each of these refrigerants incorporates advanced technologies aimed at maximizing efficiency while minimizing environmental impact, aligning with global efforts to transition to more sustainable refrigerants. These characteristics make the GE R-501F, R-404F, R-401F, and R-508F essential components in modern refrigeration technology, catering to diverse needs across various industries.