GE RAK148D1, RAK164D1 installation instructions Important safety information, Specifications

Models: RAK164D1 RAK148D1

1 16
Download 16 pages 45.41 Kb
Page 2
Image 2

Important safety information.

WARNING! Always turn off power at the main power supply before installing, cleaning or removing the thermostat.

This thermostat is for 24 VAC applications only. Do not use on voltages over 30 VAC.

All wiring must conform to local and national electrical and building codes.

Do not use air conditioning when the outdoor temperature is below 50 degrees; this can damage your A/C system and cause personal injuries.

Use this thermostat only as described in this manual.

Specifications.

Electrical rating: • 24 VAC (18–30 VAC)

1 amp maximum per terminal

4 amp maximum total load

Operating temperature range: 40°F–99°F(4°C–37°C)

Temperature set range: 60°F–85°F(15°C–29°C)

Accuracy: ± 1°F (± 0.5°C)

System configurations: 2-stage heat (RAK148D1 heat pump/resistance heat); 1-stage heat (RAK164D1 resistance heat); 1-stage cool

Timing: Anti-short cycle: 3 minutes (minimum compressor

run time/off time). Note: There may be a 3 minute minimum fan run time/off time on some models.

Terminations: R, C, W, Y, G, B (RAK148D1); R, C, W, Y, G (RAK164D1)