PROBLEM POSSIBLE CAUSE
WASHER IS NOISY
Make sure washer is level and firm to the floor with rubber foot pads in place and
front jam nuts tight. See your
Instdlatiort
Instructions.
A sharp, distinctive sound will be heard at the end of each spin period as the motor
.
stops
a’nd
the spin brake inside the transmission “locks
in.’’-Th~s
sound is normal.
Heavily unbalanced loads can cause the washer to vibrate excessively during spin,
and may cause it to move from its original position. In extreme cases (usually occurs
when washing a single, heavy item or a small load when water
level
is set higher than
necessary), the spin basket may strike the outer tub, creating a loud but harmless noise.
To correct, stop the washer by pushing in the Cycle Selector knob, open the lid and
redistribute the load evenly about the wash basket. Close the lid and restart.
I
WASHER PAUSES
Washer normally pauses between washing steps... such as between wash and spin or
IN CYCLE between spin and rinse.
If you need more
help...call,
toll free: GE Answer Center
@
/ 800.626.2000/ consumer information service

CAW

Am

CLEAN~G

USER MAINTENANCE INSTRUCTIONS

The Tub.
The porcelain is self-cleaning. Leave lid
To Store Washer.
Ask service technician to remove
open after washing to
allow
moisture to evaporate. water from drain pump and hoses to prevent freezing.
Do not use harsh or gritty cleansers. Do not store the washer where it will be exposed
The Exterior.
Wipe off any
spills
of washing to the weather.
compounds. Wipe or dust with damp cloth. Try
For Long Vacations.
Be sure water supply is shut off
not to hit surface with sharp objects.
at faucets and drain all water from hoses if weather
will be below freezing.

How to remove the agitator To remove limestone from

Filter-Flo

pan

To remove the agitator,
~
Cap
(on models so equipped)
snap the cap off and
remove the screw.
Then remove the
o
ii
Sciew
Agitator
Soak filter pan in a preheated
160°F.
(71 ‘C.)
Extender
solution of half vinegar and half water for 15
agitator extender (on
models so equipped)
and the agitator.
h
(on some models)
minutes. Then brush each side of pan with a stiff
bristle brush while flushing with running water.
— Agitator
1;
To replace the
agitator,
carefully
<)
-j/
)
.
.
,..
lower it straight down
-’
onto the shaft so that it
fits snugly into place.
Replace the agitator
i
Shafi
extender (on models (Appearance may vary)
so
equipped), the
screw and the cap.
CAUTIONS:
Do not soak in porcelain container. Vinegar can
damage porcelain.
c
Do not exceed
180°F.
(82°C.
) or filter pan
may warp.
21