GE Consumer & Industrial
Appliances
Installation Instructions
WR49X10180 Kit–Domestic
WR49X10175 Kit–International
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT – Observe all governing codes and ordinances.
Note to Installer – Be sure to leave these instructions with the Consumer.
Note to Consumer – Keep these instructions with your Owner’s Manual for future reference.
WARNING:
TOOLS AND
MATERIALS
NEEDED:
•Phillips screwdriver
•Flathead screwdriver
•5/16" hex head
•Razor knife
•Tape
•Drill
KIT CONTENTS:
•AC foil heater assembly
•Wire ties (3)
•Crimp style wire connectors (3)
•Aluminum tape –
•White vinyl tape –
•Jumper harness
•Grommet
•RTV102 (2)
•EPS beverage center
•Fresh food evaporator EPS block
•Air return EPS block
•Evaporator tube foam insulation
•Beverage center duct
•1/2” Pilot tip drill bit
To prevent electric shock, disconnect electrical power supply to refrigerator before beginning kit installation.
�������������������
The ice ball problem is being caused by very low temperatures in the lower left part of the fresh food compartment. The low temperatures are being driven by two gaps that need to be sealed. One around the beverage center duct and one along the left side curved geometry of the Quick Chill air handler cover.
These two locations need to be sealed with RTV.
REMOVE POWER TO THE UNIT BEFORE PERFORMING KIT INSTALL.
REMOVE ALL ICE AND MOISTURE FROM ALL REPAIR AREAS.
SOME 25 CU. FT. BIS MODELS DO NOT HAVE BEVERAGE CENTERS.
CHECK FOR WIRES ALREADY ROUTED WITH DC (RIGHT FRONT) HARNESS IN FRESH FOOD COMPARTMENT. IF THERE ARE WIRES THERE, A DC KIT HAS BEEN INSTALLED. IF DC KIT WAS INSTALLED ALREADY, CONNECTION TO MAIN BOARD MUST BE REMOVED AND HARNESS CUT SHORT.