GE WR49X10180 manual Step

Models: WR49X10180

1 7
Download 7 pages 27.58 Kb
Page 3
Image 3
Step 1

Step 1

Remove the bottom three bins and lower shelf in the fresh food compartment. Remove any ice inside the fresh food side of the unit. Check under the quick chill assembly. Clean and dry the area, as well as the sump.

Step 4

Apply a liberal bead of RTV along the space between the custom cool cover and the left sidewall (Figure 3). Smooth to ensure a clean appearance.

Step 2

Remove the beverage center duct cover and the evaporator line cover. Remove the fresh food evaporator cover via the three (3) screws attaching it (Figure 1). Tilt the assembly out of the way of the beverage center duct. It is not necessary to disconnect the fans. Remove any ice present and dry the area thoroughly. Should Fresh Food Evaporator EPS Block or Air Return EPS Block become damaged in this process, utilize replacement pieces in kit.

C O

L D

 

D E L I F R E S H

C

O

L

D

ES

T

Figure 3

Figure 1

Step 3

Remove Beverage Center Duct and replace with new duct from kit, liberally applying RTV to seal Duct in place. RTV completely around the Duct including behind and below, smoothing on with finger is preferred method. Cover as much of the gasket area as possible (Figure 2). Install the EPS L-insert per Figure 2.

EPS L Insert

Step 5

Apply a liberal amount of RTV102 to the underside of the 3-watt AC heater assembly. Follow the INSIDE of the lip on the bottom of the heater assembly (Figure 4). Ensure the RTV will make contact around the entirety of the heater assembly

when applied to theManual background Figure 4 custom cool cover.

Step 6

Position heater assembly on custom cool cover, making sure heater assembly is directly touching the left sidewall (Figure 5). Heater

assembly should fit custom cool cover geometry snugly.

Ensure that the heater assembly goes all the way back to the evaporator tube cover.

Figure 2

Figure 5