9ADJUST BROIL BURNER AIR ADJUSTMENT SHUTTER ON MODELS WITH A BROILER DRAWER, IF NECESSARY (See Step 8 if your range is equipped with a storage drawer.)
To determine if the bottom burner flames are burning properly, first remove the oven bottom.
Oven bottom
To remove the oven bottom:
1.Remove knurled screws holding down rear of oven bottom.
2.Grasp oven bottom at finger slots on each side.
3.Lift rear of oven bottom enough to clear the lip of range frame, then pull out.
With the oven bottom removed, properly adjusted flames should have approximately 1″ blue cones and, if range is supplied with natural gas, should burn with no yellow tipping.
(With most LP gas, small yellow tips at the end of outer cones are normal.) Flames should not lift off burner ports. If lifting is observed, gradually reduce air shutter opening until flames are stabilized.
The shutter for the oven burner is near the back wall of the oven and behind the broiler drawer.
To remove the broiler drawer:
1.Pull the drawer out until it stops, then push it back in about one inch.
2.Grasp handle, lift and pull broiler drawer out.
Loosen
Air adjustment shutter
Metal shield
Remove the metal shield at the rear of the cavity. The air adjustment shutter is behind this shield. To adjust the flow of air to the burner, loosen the
39