ZDP364NRPSS (Natural Gas)
ZDP364LRPSS (Liquid Propane)
GE Monogram® 36"
Dimensions and Installation Information (in inches)
Electrical Requirements
Ranges must be supplied with 208/240V, 60Hz, and connected to an individual, properly grounded branch circuit protected by a circuit breaker or
Universal Utility Locations
Locate gas and electric as shown
Gas Supply
• The natural gas models are designed to operate at 5" water column pressure. For proper operation, the pressure of the natural gas supplied to the regulator must be between 7" and 13" water column.
•The LP models are designed to operate at 10" water column pressure. For
proper operation, the pressure of the LP gas supplied to the regulator must be between 11" and 13" water column.
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.
Optional Backsplash Accessories
The range requires a 12" minimum clearance to a vertical combustible surface at the rear. A backsplash is required for installations with less than 12" clearance. The following backsplash accessories are available, or a custom, non- combustible backsplash can be used.
Order one with a
warming shelf
Side View with Required Backsplashes
Listed by
Underwriters
Laboratories
Specification Created 7/08 | 130555 |