GE ZGU3650 Tools Materials Required, Installation Preparation, Cut the Opening

Models: ZGU3650

1 8
Download 8 pages 18.04 Kb
Page 4
Image 4

Tools and

Materials

Required

Cut the Opening

 

 

 

Installation Preparation

 

 

 

 

 

 

 

 

 

G as Updraf t Cooktop

 

 

 

 

 

 

Self-adhesive gasket

• Carpenter’s square

• 1/2" NPT x 3/4"

• 5 foot AGA-certified

 

(supplied)

• Pipe wrench

I.D. or 1/2" I.D.

flexible metal

 

• Two clamping

• Manual gas line

flare union adaptor

appliance connec-

 

brackets and

shut-off valve

for connection to

tor, 3/4" or 1/2"

 

screws (supplied)

• 3/4" NPT x 3/4"

regulator

I.D. to match gas

 

• Gas pressure

I.D. or 1/2" NPT x

Gas-resistant pipe

supply line:

 

regulator (supplied)

1/2" I.D. flare

joint sealant

–If required by local

 

• Large flat-blade

union adaptor for

 

 

codes, use solid

 

screwdriver

connection to

 

 

pipe with fittings.

 

• Saw

supply line

 

 

 

 

 

 

 

 

Note: Purchase new

 

 

 

 

 

flexible line, DO

 

 

 

 

 

NOT USE OLD,

 

 

 

 

 

PREVIOUSLY USED

 

 

 

 

 

FLEXIBLE LINE.

 

 

 

 

 

 

8-13/16" Min.

8-13/16"

to Side Wall

Min.

4-5/8" Min.

Cutout

To Side

Cutout to Vertical

Wall

Combustible Surface

 

18-1/8"

34-1/2"

 

2-1/4"

 

Min. From

 

Front of

 

Countertop

 

Caution: Wallcoverings, countertops and cabinets should withstand 200°F heat generated by the cooktop.

Measure carefully when cutting countertop. Make sure sides of opening are parallel and rear and front cuts are exactly perpendicular to sides.

The Monogram gas updraft cooktop is designed to fit in a 36" or larger base cabinet.

The countertop cutout for cooktop must be:

34-1/2" wide

18-1/8" deep

Allow at least 4-5/8" clearance between back of cutout and wall.

Allow at least 8-13/16" clearance from right and left side of cutout to adjacent wall.

Allow at least 2-1/4" clearance between front of cutout and front edge of countertop.

Cooktop requires 3" free space below countertop.

If installing cooktop above a cabinet with drawers, it may be necessary to use a shorter length drawer to allow clearance for gas connection.

In some cases, two 3/8" I.D. 45° elbows and a pipe nipple may be added between regula- tor and cooktop to move regulator further back in order to avoid interference with drawer.

4

Page 4
Image 4
GE ZGU3650 installation instructions Tools Materials Required, Installation Preparation, Cut the Opening

ZGU3650 specifications

The GE ZGU3650 is a versatile and advanced generator set that has gained significant recognition in the energy sector. Designed to deliver reliable power for various applications, the ZGU3650 is particularly notable for its robust performance, efficiency, and cutting-edge technology.

One of the main features of the GE ZGU3650 is its high power output capability. With a capacity of up to 3650 kVA, it is designed to cater to large industrial and commercial requirements, making it ideal for critical infrastructure projects, data centers, and manufacturing facilities. This generator set can operate on various fuel types, including diesel and natural gas, providing flexibility and adaptability to different operational environments.

The ZGU3650 is equipped with advanced control systems that enhance its efficiency and operational reliability. It incorporates GE's next-generation digital control technology, allowing for real-time monitoring and control of the generator's performance. This feature ensures optimal fuel consumption while maximizing output, which not only reduces operational costs but also minimizes environmental impact.

Another standout characteristic of the ZGU3650 is its sound-attenuated enclosure. This design significantly lowers noise levels, making it suitable for use in urban or noise-sensitive environments. The generator also boasts a robust cooling system that maintains optimal operating temperatures, ensuring longevity and reducing maintenance costs.

The generator set is designed with safety as a paramount concern. It includes integrated protection features such as overload protection, short circuit protection, and fault monitoring. These systems work in conjunction to safeguard both the generator and connected load, enhancing reliability during operation.

In addition to these features, the GE ZGU3650 is built for ease of serviceability. The layout of components is designed to facilitate maintenance, with easy access to vital parts. This design consideration helps to minimize downtime, ensuring that equipment remains operational when needed.

With its combination of high power output, advanced control systems, noise reduction, and safety features, the GE ZGU3650 stands out as a leading choice for organizations that require dependable and efficient power solutions. Whether for emergency backup, prime power, or continuous operation, this generator set delivers performance that meets the demands of various industries while prioritizing sustainability and operational efficiency.