| FlavorFusion Installation Manual | |
|
|
|
|
|
| Beverage does not | No 24VAC to valves | Restore 24 VAC to valves |
|
| dispense |
|
|
|
|
|
|
|
|
|
| No CO2 pressure | Restore CO2 pressure |
|
|
|
|
|
|
|
|
|
|
|
| Beverage is too | Valve brix requires adjustment | Adjust valve brix |
|
| sweet |
|
|
|
|
|
|
|
|
|
| Carbonator is not operating | Repair carbonator |
|
|
|
|
|
|
|
| No CO2 in carbonator | Restore CO2 pressure in carbonator |
|
|
|
|
|
|
|
| City water pressure supply low or | Booster pump must be used if dynamic |
|
|
| inconsistent | water pressure drops below 40 psig. |
|
|
|
|
|
|
|
|
|
|
|
| Unit will not | CO2 pressure in carbonator tank is too | Check CO2 pressure regulator setting. |
|
| dispense | high. | 75 psig recommended. Relieve |
|
| carbonated drinks. |
| pressure from carbonator tank. |
|
| Dispenses syrup |
|
|
|
| only. |
|
|
|
|
|
|
|
|
|
| Water valve will not open | Check electrical connection to water |
|
|
|
| valve. Check resistance of coil (should |
|
|
|
| be 9 ohms). Check for voltage at coil |
|
|
|
| when brand button is depressed. |
|
|
|
|
|
|
|
|
|
|
|
| Unit will not | Carbonator tank is empty, because tank | Unplug the unit and reconnect the unit. |
|
| dispense | was emptied while power was applied | Main control board will reset, ice |
|
| carbonated drinks. | to unit. 5 minute | agitation will occur, and carbonator tank |
|
| Spurts CO2 and | pump/motor occurred, and carbonator | will refill to normal level. |
|
| syrup only. | pump is locked off. |
|
|
|
|
|
|
|
|
| Note that this can occur while the water | 1) low water pressure switch |
|
|
| filter system is serviced or water supply | deactivates carbonator pump, 2) after 5 |
|
|
| is shutoff. If drinks are drawn from the | minutes reset and retry carbonator |
|
|
| dispenser while water pressure is | pump. If water supply is restored, the 5 |
|
|
| shutoff, the carbonator pump starts and | minute timeout will not occur. Repeat |
|
|
| runs continuously, then shuts off on the | reset a second time, but on a third time, |
|
|
| 5 minute timeout. | then lockout carbonator pump, which |
|
|
|
| will generate a service call. |
|
|
|
|
|
|
|
|
|
|
|
| Carbonated drinks | CO2 is out | Replace CO2 |
|
| are flat (low on |
|
|
|
| carbonation) |
|
|
|
|
|
|
|
|
|
| Carbonator tank is 100% filled because | CO2 setting for the carbonator tank is |
|
|
| the city water pressure exceeds the | 75 psig, max water pressure is 60 psig. |
|
|
| carbonator tank CO2 pressure regulator | If necessary, install a water pressure |
|
|
| setting. | regulating valve. |
|
|
|
|
|
|
|
|
|
|
|
| Low water pressure | Could be caused by excessively long | Increase line size to 1/2” |
|
|
| runs (over 40 ft.) of 3/8” water supply |
|
|
|
| line. |
|
|
|
|
|
|
|
|
| Low water pressure | Add water pressure booster pump |
|
|
|
|
|
|
|
| Plugged water filter. | Change water filter |
|
|
|
|
|
|
|
| Water booster bladder has burst | Replace water booster tank/bladder |
|
|
|
|
|
|
|
|
|
|
|
© | - 15 - | Publication Number: 621057601INS |