Beverage does not

No 24VAC to valves

Restore 24 VAC to valves

 

 

dispense

 

 

 

 

 

 

 

 

 

 

No CO2 pressure

Restore CO2 pressure

 

 

 

 

 

 

 

 

 

 

 

 

Beverage is too

Valve brix requires adjustment

Adjust valve brix

 

 

sweet

 

 

 

 

 

 

 

 

 

 

Carbonator is not operating

Repair carbonator

 

 

 

 

 

 

 

 

No CO2 in carbonator

Restore CO2 pressure in carbonator

 

 

 

 

 

 

 

 

City water pressure supply low or

Booster pump must be used if dynamic

 

 

 

inconsistent

water pressure drops below 40 psig.

 

 

 

 

 

 

 

 

 

 

 

 

Unit will not

CO2 pressure in carbonator tank is too

Check CO2 pressure regulator setting.

 

 

dispense

high.

75 psig recommended. Relieve

 

 

carbonated drinks.

 

pressure from carbonator tank.

 

 

Dispenses syrup

 

 

 

 

only.

 

 

 

 

 

 

 

 

 

 

Water valve will not open

Check electrical connection to water

 

 

 

 

valve. Check resistance of coil (should

 

 

 

 

be 9 ohms). Check for voltage at coil

 

 

 

 

when brand button is depressed.

 

 

 

 

 

 

 

 

 

 

 

 

Unit will not

Carbonator tank is empty, because tank

Unplug the unit and reconnect the unit.

 

 

dispense

was emptied while power was applied

Main control board will reset, ice

 

 

carbonated drinks.

to unit. 5 minute time-out of carbonator

agitation will occur, and carbonator tank

 

 

Spurts CO2 and

pump/motor occurred, and carbonator

will refill to normal level.

 

 

syrup only.

pump is locked off.

 

 

 

 

 

 

 

 

 

Note that this can occur while the water

1) low water pressure switch

 

 

 

filter system is serviced or water supply

deactivates carbonator pump, 2) after 5

 

 

 

is shutoff. If drinks are drawn from the

minutes reset and retry carbonator

 

 

 

dispenser while water pressure is

pump. If water supply is restored, the 5

 

 

 

shutoff, the carbonator pump starts and

minute timeout will not occur. Repeat

 

 

 

runs continuously, then shuts off on the

reset a second time, but on a third time,

 

 

 

5 minute timeout.

then lockout carbonator pump, which

 

 

 

 

will generate a service call.

 

 

 

 

 

 

 

 

 

 

 

 

Carbonated drinks

CO2 is out

Replace CO2

 

 

are flat (low on

 

 

 

 

carbonation)

 

 

 

 

 

 

 

 

 

 

Carbonator tank is 100% filled because

CO2 setting for the carbonator tank is

 

 

 

the city water pressure exceeds the

75 psig, max water pressure is 60 psig.

 

 

 

carbonator tank CO2 pressure regulator

If necessary, install a water pressure

 

 

 

setting.

regulating valve.

 

 

 

 

 

 

 

 

 

 

 

 

Low water pressure

Could be caused by excessively long

Increase line size to 1/2”

 

 

 

runs (over 40 ft.) of 3/8” water supply

 

 

 

 

line.

 

 

 

 

 

 

 

 

 

Low water pressure

Add water pressure booster pump

 

 

 

 

 

 

 

 

Plugged water filter.

Change water filter

 

 

 

 

 

 

 

 

Water booster bladder has burst

Replace water booster tank/bladder

 

 

 

 

 

 

 

 

 

 

 