FlavorFusion Installation Manual
NOTE: See applicable Flow Diagram (see FIGURE 8) or Decal on the lower front of the unit for the location of syrup and water connections.
6.Clean the hopper interior (see CLEANING INSTRUCTIONS in Owner’s Manual).
7.Connect the unit power cord to a 120 volt, 60 cycle,
ADJUST CARBONATOR CO2 REGULATOR AND TURN WATER INLET SUPPLY
LINE ON
CAUTION: Before connecting the CO2 regulator assembly to a CO2 cylinder, turn the regulator adjusting screw to the left (counterclockwise) until all tension is relieved from the adjusting screw spring.
1.Open (counterclockwise) CO2 cylinder valve slightly to allow lines to slowly fill with gas, then open the valve fully to
2.The carbonator CO2 regulator is fixed at a nominal 75 psi.
3.Open one of the
4.Open the water inlet supply line shutoff valve.
UNIT OPERATION
WARNING: The unit must be electrically grounded to avoid possible fatal electrical shock or serious injury to the operator. The unit power cord is equipped with a
CAUTION: Never operate the carbonator pump with the water inlet supply line shutoff valve closed. “Dry running” the water pump will burn out the pump. A pump damaged in this manner is not covered by warranty.
1.Connect electrical power to the Unit.
2.Locate the switch on the junction box of the carbonator pump, and turn it ON. The water pump will start and fill the carbonator tank with carbonated water. The water pump will stop when the carbonator tank is full.
3.Check for water and CO2 leaks, and tighten any loose connections
4.Dispense several drinks until the carbonator pump cycles on. The refill time should be about
5.If the carbonator pump appears to be
Publication Number: 621057601INS | - 4 - | © |