Cornelius FlavorFusion Series installation manual Diagnostics Guide For The Main Control Board

Models: FlavorFusion Series

1 18
Download 18 pages 13.86 Kb
Page 17
Image 17
DIAGNOSTICS GUIDE FOR THE MAIN CONTROL BOARD

FlavorFusion Installation Manual

DIAGNOSTICS GUIDE FOR THE MAIN CONTROL BOARD

State

Observed State

Sensor Input

Control Response

Service Remedy

of Red LED

 

 

 

 

 

 

 

 

 

0

Flash rate 3

Both probes read “wet”

Standby mode. Pump

No service required

 

seconds

 

= OFF

 

 

 

 

 

 

1

Flash rate

Pump is OFF and

Waiting for level to

No service required

 

1/2 second

HIGH probe reads “dry”

drop below LOW

 

 

 

and LOW probe reads

probe. Pump = OFF

 

 

 

“wet”

 

 

 

 

 

 

 

2

Flash rate

Both HIGH and LOW

Normal mode.

No service required

 

1/2 second

probes read “dry”

Pump = ON

 

 

 

 

 

 

3

Flash rate

Entered when HIGH

Normal mode.

No service required

 

1/2 second

probe does not detect

Pump = ON

 

 

 

liquid, and LOW probe

 

 

 

 

does detect liquid, and

 

 

 

 

pump is ON

 

 

 

 

 

 

 

4

Flash rate 1

Entered when HIGH

THIS IS AN ERROR

- Check electrical

 

second

probe reads “wet” and

CONDITION.

connections at the

 

 

LOW probe reads “dry”

 

carbonator tank, and at

 

 

 

 

connector J4 on the

 

 

 

 

main control board

 

 

 

 

- Black wire should be

 

 

 

 

connected to the LOW

 

 

 

 

probe and also to Pin 4

 

 

 

 

of Connector J4

 

 

 

 

- Reverse the

 

 

 

 

connections if incorrect

 

 

 

 

- Replace harness if

 

 

 

 

necessary

 

 

 

 

 

5

ON

Poor signal connection

Able to continue to

Check the harness

 

continuously,

to the carbonator tank.

function but

connections of the red

 

but “flickers”

May result in short

carbonator pump

signal wire at both ends:

 

every 3

cycling of the

short-cycles. Pump

1) at the carbonator ring

 

seconds

carbonator pump.

will come on each time

terminal and

 

 

 

a drink is drawn. THIS

2) at Pin 5 of the J4

 

 

 

SITUATION SHOULD

connector at the main

 

 

 

BE CORRECTED.

control board

 

 

 

 

 

6

ON

Entered when pump

THIS IS AN ERROR

Unplug the unit and plug

 

continuously

has run continuously

CONDITION.

it back in. This will reset

 

 

for 5 minutes

 

the unit's main control

 

 

 

 

board and restart the

 

 

 

 

carbonator pump.

 

 

 

 

 

© 2005-2006, IMI Cornelius Inc.

- 17 -

Publication Number: 621057601INS