FlavorFusion Installation Manual
No Syrup or | Syrup supply is empty | Replace BIB |
Watered down drink |
|
|
dispensed |
|
|
|
|
|
| BIB pump not working | Replace BIB pump |
|
|
|
| No CO2 or compressed air supply to | Check CO2 pressure regulator setting. |
| BIB pump, or not enough pressure | 65 psig recommended. Replace CO2 |
|
| tank or fix compressor. |
|
|
|
|
| |
| Carbonator Troubleshooting | |
|
|
|
Symptom | Cause | Remedy |
|
|
|
Carbonator pump | Power cord for the carbonator pump | Carbonator pump is powered off the |
does not start to fill | motor is not connected. | main control board inside the electrical |
tank |
| box of the unit. Check that the umbilical |
|
| cord is connected from the unit to the |
|
| pump motor terminal box. |
|
|
|
|
|
|
Power cord is | Carbonator pump motor is disabled. | Check the enable/disable switch on the |
connected but |
| carbonator pump terminal box and |
carbonator pump |
| enable it, if necessary. |
does not run. |
|
|
|
|
|
| Probes were dry, unit was powered up, | This results in a 5 minute timeout. |
| water was not turned on, and | Unplugging the unit and plugging it in |
| carbonator did not fill. | will reset the unit and start the |
|
| carbonator pump. |
|
|
|
| Water service was interrupted for more | Unplugging the unit and plugging it in |
| than 5 minutes. | will reset the unit and start the |
|
| carbonator pump. |
|
|
|
|
|
|
Carbonator pump is | Lower liquid level probe reads “dry” | Check color of leads going to probes. |
short cycling with | while upper probe reads “wet” | Black should go to bottom probe and |
every drink drawn |
| white to top probe. Reverse if incorrect. |
|
|
|
|
|
|
Carbonator tank | A. Poor electrical connections between | A. Check connections at carbonator |
overfills, overflows | carbonator tank and main control board | tank and at connector J4 on the main |
through relief valve, |
| control board. |
and pump shuts off |
|
|
after 5 minutes. |
|
|
|
|
|
| B. Broken wires between carbonator | B. Replace wire harness |
| tank and main control board |
|
|
|
|
| C. Defective liquid level probes | C. Replace both liquid level probes |
|
|
|
Publication Number: 621057601INS | - 16 - | © |