ZISB360DM – GE Monogram 36" Built-In Refrigerator
with Dispenser and Water Filter

35-1/2

7"

5"

Electrical

Area

84 1/2" max

83 1/2" min

Finished

Opening 74" From Floor

to Bottom

of Electrical

24"

5" 5" 3 1/2"

Water Supply

3 1/2"

36" Models 12"

THE INSTALLATION SPACE
*84" From
Floor to
Top Frame
36"
Frame to Frame
35"
Case Width
*83-1/2"
at
Rear
*Shipping height.
The refrigerator can
be adjusted to fit
into a cutout that is
83-1/2" min. to 84-1/2"
max. height. Note
that the top case
trim at the front is
1/2" higher and will
overlap upper
cabinetry or soffit.
Use leveling legs
and wheels for
height adjustment.
As an ENERGY STAR
®
Partner,
GE has determined that this product
meets the ENERGY STAR
®
guidelines for energy efficiency.
15"
13"
23-7/8"
Behind
Frame
20-5/8
Product Clearances
These refrigerators are equipped with a 2 position door
stop. The factory set 130° door swing can be adjusted to 90°
if clearance to adjacent cabinets or walls is restricted.
Allow minimum clearances for freezer door and fresh food
door for a full 130° door swing and to allow for pan removal.
4" minimum clearance is required when door swing is adjusted
to 90°.If the 90° door stop position is used, pan access is
maintained, but pan removal is restricted.
Water And Electrical Locations
The opening must be prepared with the electrical and water
supply located as shown.
The cutout depth must be 24".
Designed for industry standard flush installation. The refrigerator
will project forward, slightly beyond adjacent cabinetry,
depending on your installation.
The cutout depth beneath a soffit:
When installed beneath a soffit, the soffit cannot exceed
the 24" installation depth shown. The top case trim overlaps
the bottom of the soffit.
Frameless cabinets:
The case trim overlaps cabinets at the top and sides.
Therefore, frameless cabinets may require filler strips to
prevent interference with cabinet door swing. The opening
must allow for filler strips.
Additional Specifications
A 115 volt 60Hz., 15 or 20 amp power supply is required. An
individual properly grounded branch circuit or circuit
breaker is recommended. Install a properly grounded 3-prong
electrical receptacle recessed into the back wall.
Electrical must be located on rear wall as shown.
Note: GFI (ground fault interrupter) is not recommended.
Water line can enter the opening through the floor or back wall.
The water line should be 1/4" O.D. copper tubing between
the cold water line and water connection location, long
enough to extend to the front of the refrigerator. Installation
of an easily accessible shut off valve in the water line
is recommended.
For answers to your Monogram,
® GE Profileor
GE appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center®service, 800.626.2000.
R
Listed by
Underwriters
Laboratories
Specification Revised 8/02