Monogram.™
Dimensions and Specifications (in inches)
7” Min.
| |
Hood | |
| Width |
Soffit Framing:
We recommend that the vent hood and/or duct cover be on site before final framing and wall finishing to more accurately locate the ductwork and electrical service.
Note: If the top of the installation location does not meet the soffit, use a 6" or 12" duct cover accessory
to conceal the duct run.
•The soffit should be constructed with 2 x 4s.
•Determine the installation location.
•Refer to “Soffit Installation” for mounting screw locations.
•Mark the centerline of the installation.
•Add additional 2 x 4 studs at the locations illustrated.
•Allow 7" deep minimum opening below the soffit to accommodate ductwork.
•Cut two wood shims, 2" x 10" x drywall thickness. Secure to the bottom of the horizontal studs, flush with the front, as illustrated. Note: If drywall is present, cut away enough to expose studs.
Shims
Finished Drywall
Created 1/98