![Wall Mount Framing:](/images/new-backgrounds/197033/1970335x1.webp)
Monogram.™
Dimensions and Specifications (in inches)
7" Min.
Hood
Width
No Additional
Wall Studs needed
7" Min.
Hood
Width
Plywood Sheet
(Wall Hole Cut
Out x Drywall
Thickness)
Additional
Wall Studs
Installed
Wall Mount Framing:
Note: A decorative duct cover is available for wall mount installations. The duct cover conceals the duct run from the top of the hood to the ceiling. Choose the 6" or 12" cover based upon installation height of the vent hood.
We recommend that the vent hood and decorative duct cover be on site before final framing and wall finishing in order to accurately locate the ductwork and electrical service.
•Determine the location for installation.
•Mark the centerline of the installation.
Cut a sheet of plywood 30" wide and 18" high. If drywall is installed, cut away enough to expose two vertical studs, one on each side of the cutout. Secure the plywood to the studs.
• Install additional aligning wall studs as illustrated.
Rear View of Vent Hood
|
| Ceiling Drywall |
|
| 6" or 12" |
|
| Duct |
|
| Cover |
Hood Centerline | ||
18" |
| |
| ||
| C | |
|
| |
| L |
|
|
Centerline of
Installation
Space
Created 1/98
For answers to your Monogram,®GE Profile Performance Series,™ GE Profile,™ GE, Hotpoint and RCA appliance questions, call GE Answer Center® service, 800.626.2000.