STEP 10 CONNECT WATER SUPPLY

Installation Instructions

STEP 10 CONNECT WATER SUPPLY

Check to be sure that refrigerator power cord is not plugged into the wall outlet.

House

Refrigerator

Water Supply

Water Supply

Locate and bring copper tubing to the front of the cabinet.

Turn the water on to flush debris from line. Run about a quart of water through tubing into a bucket, then shut-off water.

Slip a 1/4" nut and ferrule (provided) over both ends of the copper tubing. Insert tube into the union fitting on the unit and tighten nut to union.

Turn on the water to check for leaks.

Note: Make sure excess tubing length does not interfere with drawer closing or toekick installation.

STEP 11 CONNECT POWER

Connect refrigerator power cord plug to a properly grounded receptacle, accessible through the top left side of the grille opening.

Raise

Grille

Panel

Electrical

Sabbath / Light

Outlet

Switch

Check to make sure power to refrigerator is on by opening refrigerator door to see if interior lights are on.

The temperature controls are preset at 37°F for the fresh food section and 0°F for the freezer.

Allow 24 hours to stabilize before making adjustments.

16

STEP 12 START ICEMAKER

STEP 11 CONNECT POWER Power Switch

STEP 12 START ICEMAKER Feeler Arm

Flip the switch to I (ON). The icemaker will begin operation automatically.

Be sure nothing interferes with the sweep of the feeler arm.

Discard the first full bucket of ice cubes.

To turn the icemaker off, set the switch to O (OFF).

STEP 13 INSTALL TOEKICK

Locate the supplied toekick (shipped taped to the side of the refrigerator). Install with 2 screws provided, adjust to desired height and tighten screws.

A custom toekick can be installed to match or complement the surrounding cabinetry. Use the supplied toekick as a template to cut out the notch and vent holes.

Supplied Toekick

1/4" or Thicker Toekick

Important: The vented toekick must remain unob- structed for proper air circulation and refrigerator operation.