Monogram.™
ZIR36ND–GE Monogram 36" Built-In All-Refrigerator
Product Dimensions (in inches)
10" Min.
4"
35" Case
36" Overall
Design Information
Designed to be installed flush or
•Field installed custom panels, Lexan® or stainless steel panels are required. The door and grille panel sizes vary to accommodate the kit being used.
•The supplied toekick is vented and must remain unobstructed for proper air circulation.
Optional Panel Kits:
•ZWBR36: Black Lexan® Panel Kit
•ZWWR36: White Lexan® Panel Kit
•ZWSR36: Stainless Steel Panel Kit
Optional Custom Trim Kits:
• ZKHR1: For installation of a custom handle of your choice onto a 1/4" Panel. |
• ZKTR36LH or ZKTR36RH: For installation of a 3/4" thick custom panel. |
• ZKHTR1: For installation of a custom handle of your choice onto a 3/4" thick |
panel. (This kit must be used in combination with ZKTR36LH or ZKTR36RH). |
• ZKHRSS1: Tubular Stainless Steel handle for 1/4" thick panel. |
• ZKHTRSS1: Tubular Stainless Steel handle for 3/4" thick panel. |
• ZGC2: 1/4" grille panel frame side pieces for |
|
| *Finished Width |
| |||||||
|
| 7 1/2" |
|
|
| Electrical | Wall View | |||
|
|
|
|
| Area |
| ||||
|
|
|
|
|
| |||||
| 7" |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
| 5" |
|
|
| ||||||
84 1/2" max |
| 24 3/4" Total |
| 74" From Floor | ||||||
83 1/2" min |
| Depth |
| to Bottom | ||||||
Finished |
|
|
|
|
|
|
|
|
| of Electrical |
Opening |
|
|
|
|
|
|
|
|
|
|
| 5" |
|
| Water Supply 5" | 3 1/2" | |||||
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
3 1/2"
*36" Min. for a flush installation into an enclosure.
*
heights. (Factory set for 84"). |
• ZWT1: White toekick (supplied toekick is black). |
• ZFC1: Trim strip for |
two products. |
Additional Specifications
•A 115 volt 60Hz., 15 or 20 amp power supply is required. An individual properly grounded branch circuit or circuit breaker is recommended. Install a properly grounded
•Water line can enter opening through the floor or back wall. The water line should be 1/4" O.D. copper tubing between the cold water line and water connection location, long enough to extend to the front of the refrigerator. Installation of an easily accessible shut off valve is recommended.
Clearances:
•If the refrigerator or freezer is installed in a corner:
A 4" clearance is required on the hinge side for a 90° door opening and access to fresh food drawers. A 10" clearance is required on the hinge side to remove pans.
For answers to your Monogram,®
GE Profile Performance Series,™
GE Profile™ or GE appliance questions, call
GE Answer Center® service, 800.626.2000.
Specification Created 8/00
Listed by
Underwriters
RLaboratories