ZV30RSFSS – GE Monogram 30" Stainless Steel Professional Hood
Advanced Planning
Ductwork Planning
•These vent hoods are equipped for 10" round ductwork. In most instances they may be transitioned to 8" round.
•This hood may be vented vertically through upper cabinets, soffit or ceiling. A duct transition piece is supplied for vertical exhaust. Use locally supplied elbows to vent horizontally through the rear wall.
•Determine the exact location of the vent hood.
•Plan the route for venting exhaust to the outdoors.
•Use the shortest and straightest duct route possible. For satisfactory performance, duct run should not exceed 150 ft. equivalent length for any duct configurations.
•Refer to “Duct Fittings” chart to compute the maximum permissible length for duct runs to the outdoors.
•Use metal ductwork only.
•Install a wall cap or roof cap with damper at the exterior opening. Order the wall or roof cap and any transition needed in advance.
Wall Framing for Adequate Support
•These vent hoods are heavy. Adequate structural support must be provided. Hoods must be secured to vertical studs in the wall.
•It is strongly recommended that the vent hood with duct cover be on site before final framing and wall finishing. This will also help to accurately locate the ductwork and electrical service.
Decorative Duct Covers:
Decorative duct covers, 6" and 12" high, are available to fit all models. The duct cover conceals the ductwork running from the top of the hood to the ceiling or soffit. Stack one or more duct covers over the top of the hood to reach your ceiling height.
POWER SUPPLY
IMPORTANT – (Please read carefully)
WARNING: FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before beginning installation.
Do not use an extension cord or adapter plug with this appliance. Follow national electrical codes or prevailing local codes and ordinances.
Electric supply
These vent hoods must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or time delay fuse.
•Wiring must be 2 wire with ground.
•If the electrical supply does not meet the above requirements, call a licensed electrician before proceeding.
•Route house wiring as close to the installation location as possible on the back wall or ceiling.
•Connect the wiring to the house wiring in accordance with local codes.
Grounding instructions
The grounding conductor must be connected to a ground metal, permanent wiring system, or an
WARNING: The improper connection of the
Optional Duct Cover Accessories
6" Duct Cover
12" Duct Cover
Decorative duct covers are available in 6" and 12" heights. Duct covers may be stacked, in various combinations, to conceal the ductwork running from the top of the hood to the ceiling.
•Before you begin, you should determine the installation height of the hood and order the correct size duct cover. The duct covers should be ordered at the same time as the vent hood and be on site before installation. Order the duct cover corresponding to your model.
Specification Created 10/02
6" Duct Covers |
|
|
Hood Model | 6" Duct Cover | Dimensions |
ZV48R | ZX48DC6 | 6"H x |
ZV36R | ZX36DC6 | 6"H x |
ZV30R | ZX36DC6 | 6"H x |
12" Duct Covers |
|
|
Hood Model | 12" Duct Cover | Dimensions |
ZV48R | ZX48DC12 | 12"H x |
ZV36R | ZX36DC12 | 12"H x |
ZV30R | ZX36DC12 | 12"H x |
|
| For answers to your Monogram,® GE Profile™ or | |
| Listed by | GE appliance questions, visit our website at | |
| Underwriters | GEAppliances.com or call | |
R | Laboratories | ||
GE Answer Center® service, 800.626.2000. | |||
|
|