Gefen CAT5 user manual Service Switch Usage Guide, Setting

Models: CAT5

1 18
Download 18 pages 60.27 Kb
Page 13
Image 13
SERVICE SWITCH USAGE GUIDE

SERVICE SWITCH USAGE GUIDE

Gefen CAT5 HD products (sender and receiver) both contain a pair of service switches (also called dip switches) located underneath the unit. These service switches are used to select from sets of configurations that will equalize the signal to best match the conditions in your setup. For the CAT5•7500HD, there are 1 set of switches for each monitor under both the sender and receiver units. The switches are hidden beneath black stickers. Each bank of dip switches have 4 switches. Switches 3 and 4 are not used. (*Note: Adjustments should be done with sources and display on.)

Sender Dip Swich Settings

Setting

Switch 1

Switch 2

No Boost

OFF

ON

Normal Boost (Default)

OFF

OFF

Strong Boost

ON

OFF

Undefined

ON

ON

 

 

Receiver Dip Swich Settings

 

Setting

Switch 1

Switch 2

No EQ (Default)

OFF

OFF

EQ Setting 2

ON

OFF

EQ Setting 3

OFF

ON

Maximum EQ

ON

ON

Adjustment Guidelines:

1)Strong boost should not be used on stranded cables. Strong boosting will cause pixels or no picture on these cables.

2)Using the wrong settings will not damage the units; it will either produce no image or a noisy image.

3)To elminate the possibility of cross talk and interference, cables must be terminated with 568B scheduling. (See page 9 for details)

10

Page 13
Image 13
Gefen CAT5 user manual Service Switch Usage Guide, Setting