Citizen Systems iDP3110 DIP Switch Setting, Serial Interface Type, Off, Parallel Interface Type

Models: iDP3110

1 36
Download 36 pages 18.35 Kb
Page 23
Image 23

iDP3110 User's Manual

7. DIP SWITCH SETTING

7.1 Serial Interface Type

Switch

Functions

OFF

ON

Shipping

NO.

 

 

 

Setting

 

 

 

 

 

1

Character direction

Normal

Inverted

OFF

 

selection

character

character

 

 

 

 

 

 

2

Baud rate selection

9600 BPS

4800 BPS

ON

 

 

 

 

 

3,4

Not used

 

 

OFF

 

 

 

 

 

7.2 Parallel Interface Type

Switch

Function

OFF

ON

Shipping

NO.

 

 

 

Setting

 

 

 

 

 

1

Character direction

Normal

Inverted

OFF

 

selection

Character

character

 

 

 

 

 

 

 

 

2

Print command

CR

LF

OFF

 

selection

 

 

 

 

 

 

 

 

3, 4

Not used

 

 

OFF

 

 

 

 

 

Dip switch position

The Arrow mark in the figure below indicates the location of the dip switch with the printer cover removed. Power switch OFF the printer before altering the settings.

CITIZEN

18

Page 23
Image 23
Citizen Systems iDP3110 manual DIP Switch Setting, Serial Interface Type, Off, Parallel Interface Type, Dip switch position