d-2) Multiple character registration
By repeating the single character registration, a maximum of 8 characters can be registered.
When defining multiple characters in a successive address (character code), register pattern data for a
maximum of 8 characters by designation A1 as the starting address and A2 as the ending address.
Note) A1<A2, A2-A17
[Pattern data configuration]
d-3) In case of iDP3110-24* (24 columns) specification
Pattern data to be registered must consist of 6 bytes per charac ter. That is, pattern data configured by
a 6 × 8 dot matrix is broken up into 6 vertically positioned units each of which is represented by 1
byte of data. All together, 6 bytes of data are transmitted.
<Example> When transmitting the following data,