35
PATTERN SUMMARY
There are four options under the System Setup pattern. Use the or buttons to
select the desired option. Press the [OPTION] button to accept the selection.
1 Copy OUT EDID to IN EDID
Copies the EDID from the device/display connected to the HD Pattern Signal
Generator and stores it in a local buffer on the unit. The EDID can be uploaded
to another output device.
The EDID data is stored in volatile memory. Any power disruption will
erase the contents of the buffer.
2 Copy IN EDID to OUT EDID
Copies the EDID data stored in the local buffer (using the Copy OUT EDID to
IN EDID option), to the device connected to the output of the HD Pattern Signal
Generator.
3 IR Remote Address
Changes the IR channel of the HD Pattern Signal Generator, when used with
the IR Remote Control Unit. An IR Remote Control Unit is not included with this
product at this time.
4 Exit
Returns to the rst screen of the System Setup pattern.