52
HD PATTERN SIGNAL GENERATOR SOFTWARE
Source selection
buttons
EDID Read / Write
The HD Pattern Signal Generator has the ability to read EDID data. EDID data
can also be saved, loaded, written, erased, compared, interpreted, and summed.
Each of these features will be covered in this section. Clicking the EDID Read /
Write button will display the following screen:
Reading EDID
1. Select the Source by clicking one of the three radio buttons at the top portion
of the screen.
EDID can be read from a downstream sink (display, etc) or from the EDID
stored in the HD Pattern Signal Generator. Click HDMI/DVI Out or VGA Out
to read the downstream EDID. Click the HDMI / DVI In radio button to read
the EDID stored in the HD Pattern Signal Generator.