OPERATION NOTES

OPERATION NOTES

READ THESE NOTES BEFORE INSTALLING OR

OPERATING THE A/V CINEMA SCALER PRO

Audio from the analog DB-25 input is available in bypass mode only. No video will be output when using the bypass mode.

Audio connection for each input is selectable between analog and digital. Selection of the audio input type is selectable using the front panel LCD menu system. For more information please see page 18.

Coaxial/Optical Digital Audio Format Support

2 Channel LPCM:

32kHz – 96kHz

Multi-Channel AC-3

1-6 Channels Bitstream

HDMI Digital Audio Format Support

2 Channel LPCM

32kHz – 96kHz

Multi-Channel AC-3

1-6 Channels Bitstream

8 Channel LPCM

32kHz - 96kHz

Audio Processing

Dolby Pro Logic II *All analog/digital (No DB-25) inputs. (See page 16 for a detailed description of this feature)

Maximum supported video input formats

DVI-D:

Maximum resolution 1920x1200/60Hz

DVI-I:

Maximum resolution 1920x1200/60Hz (both analog and digital)

Component:

Maximum resolution 1920x1080/60Hz

VGA:

Maximum resolution 1920x1200/60Hz

HDMI:

Maximum resolution 1920x1080/60Hz

Supported video output formats:

Digital:

1920x1080p 24/50/60Hz and 2K (2048x1080p 24/50/60Hz)

Analog:

1920x1080p 24/50/60Hz and 2K (2048x1080p 24/50/60Hz)

23.97/24/50/60Hz passthrough is supported via all inputs. (Detailed timings can be found on page 13)

Supported audio output formats:

Analog: 8 channel discrete (balanced over DB-25)

This product is fully HDCP compliant