Genelec 7050A Operating Manual, System Specifications, Crossover Section, Amplifier Section

Models: 7050A

1 4
Download 4 pages 5.78 Kb
Page 4
Image 4
7050A Operating Manual

7050A Operating Manual

SYSTEM SPECIFICATIONS

 

7050A

Free field frequency response

 

(+/- 3 dB)

38 Hz…85 Hz

 

 

Maximum short term sine wave

 

SPL output averaged from

 

45 to 85 Hz, measured in

 

half space at 1 meter

100 dB SPL

 

 

Maximum peak SPL output with

 

random pink noise, measured

 

in half space at 1 meter

105 dB SPL

 

 

Self generated noise level in

 

free field @ 1 m on axis

 

(a-weighted)

15 dB

 

 

Harmonic distortion

@ 95 dB SPL

at @ 1 m on axis in half space

40 … 85 Hz

2nd

3 %

3rd

2 %

 

 

Driver, magnetically shielded

200 mm (8”)

 

 

Weight

15 kg (33 lbs)

 

 

Dimensions

 

Height

410 mm (16 1/8”)

Width

350 mm (13 3/4”)

Depth

314 mm (12 3/8”)

 

 

CROSSOVER SECTION

 

7050A

 

 

Subsonic filter

 

(18 dB/octave) below

38 Hz

 

 

Crossover frequency,

 

(sub/main channels)

85 Hz

AMPLIFIER SECTION

 

7050A

 

 

Short term amplifier output

 

power (Long term output power

 

is limited by driver unit

 

protection circuitry)

70 W

 

 

Amplifier system distortion

 

at nominal output

 

THD

0.08%

 

 

Mains voltage

230 V, 115/230V or 100/200V

 

according to region

 

 

Power consumption (average)

 

Idle

10 VA

Full output

100 VA

INPUT SECTION

 

7050A

Input connector XLR female

 

pin 1

gnd

pin 2

+

pin 3

 

 

Input impedance

10 kohm balanced

 

 

Input level for 100 dB SPL

 

output @ 1 m

0…–18 dB (referenced to 1029/2029 output)

CONTROLS

 

7050A

 

 

 

 

 

 

Input sensitivity

 

0…–18 dB

 

 

 

Genelec Document D0045R001. Copyright Genelec Oy 5.2002. All data subject to change without prior notice

International enquiries:

In the U.S. please contact

 

Genelec, Olvitie 5

Genelec, Inc., 7 Tech Circle

 

FIN-74100, Iisalmi, Finland

Natick, MA 01760

 

Phone +358 17 83 881

Phone +1 508 652 0900

 

Fax +358 17 812 267

Fax +1 508 652 0909

www.genelec.com

Email genelec@genelec.com