Generac Portable Products 5500EXL Extended Life Generator

GENERAL MAINTENANCE RECOMMENDATIONS

The owner/operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis; that all discrepancies are corrected; and that the unit is kept clean and properly stored. Never operate a damaged or defective generator.

Engine Maintenance

See engine manual for instructions.

Generator Maintenance

Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves or any other foreign material.

Check the cleanliness of the generator frequently and clean when dust, dirt, oil, moisture or other foreign substances are visible on its exterior surface.

NOTE: Do Not use a garden hose to clean generator. Water can enter engine fuel system and cause problems. In addition, if water enters generator through cooling air slots, some of the water will be retained in voids and cracks of the rotor and stator winding insulation. Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.

Clean the Generator

Use a damp cloth or soft bristle brush to wipe exterior surfaces clean.

A vacuum cleaner may be used to pick up loose dirt and debris.

Low pressure air (not to exceed 25 psi) may be used to blow away dirt. Inspect cooling air slots and opening on generator. These openings must be kept clean and unobstructed.

SERVICE/ADJUSTMENTS

Refer to engine owner’s manual for information.

STORAGE

The generator should be started at least once every seven days and allowed to run at least 30 minutes.

If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage.

Generator Storage

Clean the generator as outlined in “To Clean the Generator.”

Check that cooling air slots and openings on generator are open and unobstructed.

Disconnect the negative battery cable from the battery.

DANGER: Storage covers can be flammable. Do Not place a storage cover over a hot generator. Let the unit cool for a sufficient time before placing the cover on the unit.

Engine Storage

See engine owner’s manual for instructions on how to properly store the engine.

Other Storage Tips

Do Not store gasoline from one season to another.

Replace your gasoline can if it starts to rust. Rust and/or dirt in a gasoline can cause problems when you use contaminated fuel with this unit.

Store in clean and dry area.

SPECIFICATIONS

Rated Maximum Continuous

AC Power Output. . . . . . . . . . . . 5500 watts (5.5 kW) Rated AC Voltage . . . . . . . . . . . 120/240 Volts Rated Maximum AC Current:

at 240 Volts. . . . . . . . . . . . . . . 22.9 Amperes

at 120 Volts. . . . . . . . . . . . . . . 45.8 Amperes

Phase . . . . . . . . . . . . . . . . . . . . 1

Rated AC Frequency . . . . . . . . . 60 Hertz

Number of Rotor Poles . . . . . . . 2

Driven Speed of Rotor . . . . . . . . 3600 RPM

12

Page 12
Image 12
Generac 5500EXL manual General Maintenance Recommendations, SERVICE/ADJUSTMENTS Storage, Specifications