Generac Portable Products 7000EXL Extended Life Generator
SPECIFICATIONS
Maximum Surge Watts . . . . . . . . . . . . . . . | .12,250 watts |
Continuous Wattage Capacity . . . . . . . . . | . .7,000 watts |
Power Factor . . . . . . . . . . . . . . . . . . . . . | . . . . . . . . .1.0 |
Rated Maximum Continuous AC Load Current: | |
At 120 Volts . . . . . . . . . . . . . . . . . . . . | . . .58.3 Amps |
At 240 Volts . . . . . . . . . . . . . . . . . . . . | . . .29.2 Amps |
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . | |
Rated Frequency . . . . . . . . . . . . . . . . . . . | . . . .60 Hertz |
Fuel Tank Capacity . . . . . . . . . . . . . . . . . . . | 7 U.S. gallons |
Shipping Weight . . . . . . . . . . . . . . . . . . . . | . . . . .240 lbs. |
GENERAL MAINTENANCE RECOMMENDATIONS
The Owner/Operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis; that all discrepancies are corrected; and that the unit is kept clean and properly stored. Never operate a
damaged or defective generator.Engine Maintenance
See engine owner’s manual for instructions.
CAUTION! Avoid prolonged or repeated skin contact with used motor oil. Used motor oil has been shown to cause skin cancer in certain laboratory animals.Thoroughly wash exposed areas with soap and water.
KEEP OUT OF REACH OF CHILDREN. DON'T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION CENTERS.
Generator Maintenance
Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves or any other foreign material.
NOTE: Do Not use a garden hose to clean generator. Water can enter engine fuel system and cause problems. In addition, if water enters generator through cooling air slots, some of the water will be retained in voids and cracks of the rotor and stator winding insulation.Water and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.
Battery Maintenance
Other than float charging, described elsewhere, no maintenance is required for the battery. Keep the battery and terminals clean and dry.
IMPORTANT: Battery charging should be performed in a dry location, such as inside a garage.
To Clean the Generator
•Use a damp cloth to wipe exterior surfaces clean.
•A soft bristle brush may be used to loosen caked on dirt or oil.
•A vacuum cleaner may be used to pick up loose dirt.
•Low pressure air (not to exceed 25 psi) may be used to blow away dirt. Inspect cooling air slots and opening on generator.These openings must be kept clean and unobstructed.