Generac Portable Products 7000EXL Extended Life Generator

OPERATING THE

4.Place the choke lever in the “Full” choke position (Figure 7).

GENERATOR

Figure 7 — Choke Positions

CAUTION! Never start or stop unit with electrical loads connected AND with the connected devices turned ON.

IMPORTANT: Always unplug the battery float charger before starting the generator.

Starting the Engine

Disconnect all electrical loads from the generator. Use the following start instruction steps by numerical order:

1.Turn the fuel valve to the “On” position (Figure 4).

Figure 4 — Fuel Valve

Fuel Valve is shown in the On position

2.Make sure the Idle Control switch is in “Off” position (Figure 5).

Figure 5 — Idle Control Switch

3.Set the Run/Stop switch to “Run” position (Figure 6).

Figure 6 — Run/Stop Switch

5A. For electric starting, press start switch on generator cradle.To prolong the life of the starter components, press the starter button for no more than 15 seconds, and pause for 30 seconds.

5B. For manual starting, grasp the recoil handle and pull slowly until slight resistance is felt.Then pull rapidly one time only to start engine.

If engine starts, proceed to step 7.

If engine fails to start, proceed to step 6.

6.Move the choke lever to “Half” choke position, and pull recoil handle twice.

If engine fails to start, repeat steps 4 thru 6.

7.Move choke lever to “Run” position. If engine falters, move choke lever to “Half” choke position until the engine runs smoothly and then to “Run” position.

NOTE: If engine still fails to start after 3 pulls, check for proper oil level in crankcase.This unit is equipped with a Low Oil Shutdown System. See engine manual.

Refer to the engine owner’s manual for complete starting instructions.

Connecting Electrical Loads

Let engine stabilize and warm up for a few minutes after starting.

Plug in and turn on the desired 120 and/or 240 Volt AC, single phase, 60 Hz electrical loads.

Do Not connect 240 Volt loads to the 120 Volt receptacles.

Do Not connect 3–phase loads to the generator.

Do Not connect 50 Hz loads to the generator.

7