STORAGE
The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than
30 days, use the following guidelines to prepare it for storage.
Generator Storage
•Clean the generator as outlined in “To Clean the Generator.”
•Check that cooling air slots and openings on generator are open and unobstructed.
CAUTION! Storage covers can be flammable. Do Not place a storage cover over a hot generator. Let the unit cool for a sufficient time before placing the cover on the unit.
Engine Storage
See engine owner’s manual for instructions.
Other Storage Tips
•To prevent gum from forming in fuel system or on essential carburetor parts, empty all three supplied fuel stabilizer containers into fuel tank and fill with fresh gasoline. Run the unit for several minutes to circulate the additive through the carburetor.The unit and fuel can then be stored for up to 24 months.Additional fuel stabilizer can be purchased locally.
•Do Not store gasoline from one season to another unless it has been treated as described above.
•Replace gasoline can if it starts to rust. Rust and/or dirt in gasoline can cause problems when that fuel is used with this unit.
•Store in clean and dry area.