Generac 7500 Volt AC, 50 Amp Receptacle, 120/240 Volt AC, 30 Amp Locking Receptacle, NEMA L5-30

Models: 7500

1 20
Download 20 pages 54.03 Kb
Page 10
Image 10
240 Volt AC, 50 Amp Receptacle

Generac Portable Products 7500EXL Extended Life Generator

3-Wire Cord Set

Neutral

120V

Hot

This receptacle powers 120 Volt AC, single phase, 60 Hz loads requiring up to 3,600 watts of power

(3.6 kW). Or it will operate 240 Volt AC, single phase, 60 Hz loads up to 7,200 watts 7.2 kW). The outlet is protected by a 30 Amp push-to-reset circuit breaker.

240 Volt AC, 50 Amp Receptacle

Use a NEMA 14-50plug with this receptacle Connect a 4-wire cord set rated for 240 Volt AC loads at

50 Amps to the plug (Figure 12).

_=========240 Volts A¢ ===========_

NEMA L5-30

r7_7 Ground

(Green)

Use this receptacle to operate 120 Volt AC, 60 Hz, single phase loads requiring up to 3600 watts (3.6 kW) of power at 30 Amps. The outlet is protected by a 30 Amp push-to-reset circuit breaker.

120/240 Volt AC, 30 Amp Locking

Receptacle

Use a NEMA L14-30 plug with this receptacle. Connect a 4=wire cord set rated for 250 Volt AC loads at 30 Amps or greater. You can use the same 4-wire cord if you plan to run a 120 Volt load (Figure 11)

4-WireCord Set

NEMA ]4-50

Y (Hot)

X (Hot)

Ground

NEMA L14-30(Green)

Use this receptacle to operate 240 Volt AC, 60 Hz, single phase loads requiring up to 7,500 watts (7.5 kW) of power.

A CAUTION! Although this outlet states it has a 250 Volt 50 Amp rating (up to 12,500 watts), the generator is only rated for 7,500 Watts. Powering loads that exceed the wattage/ amperage capacity of the generator can damage it or cause serious injuries. 240 Volt loads powered through this outlet should not exceed 31.2 Amps of current draw.

/

10

Page 10
Image 10
Generac 7500 Volt AC, 50 Amp Receptacle, 120/240 Volt AC, 30 Amp Locking Receptacle, NEMA L5-30, NEMA L14-30Green