KNOW YOUR GENERATOR

GeneracPortableProducts7500EXLExtendedLifeGenerator

KNOW YOUR GENERATOR

Read this owner's manual and safety rules before operating your generator.

Compare the illustrations with your generator to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference

Circuit Breakers (AC)

 

Electric Start

Button

 

 

12 Volt DC

 

Recoil

Starter

 

 

Receptacle

 

 

 

 

Idle Control Switch

 

Choke

Lever

 

 

 

 

120 Volt AC,

 

Run/Stop

Switch

30 Amp Locking

 

 

 

 

Receptacle

 

 

 

 

 

 

Spark Arrestor Muffler

 

/

 

 

 

120/240 Volt AC, 30 Amp

/

 

 

 

Locking Receptacle

/

 

 

 

 

240 Volt AC, 50 Amp

120 Volt AC, 20 Amp

Receptacle

 

 

Receptacles

Grounding

Wing Nut

 

 

 

 

 

 

12 Volt DC Receptacle i Use this receptacle with battery charge cables to charge a 12 Volt battery.

120 Volt AC, 20 Amp Receptacles May be used to supply electrical power for the operation of 120 Volt

AC, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.

120 Volt AC, 30 Amp Locking Receptacle i May be used to supply electrical power for the operation of

120 Volt AC, 30 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.

120/240 Volt AC, 30 Amp Locking Receptacle --May be used to supply electrical power for the operation of 120 and/or 240 Volt AC, 30 Amp, single

phase, 60 Hz electrical lighting, appliance, tool and motor loads.

240 Volt AC, 50 Amp Receptacle i May be used to supply electrical power for the operation of 240 Volt AC, 50 Amp, single phase, 60 Hz electrical loads.

Choke Lever Used when starting a cold engine.

Circuit Breakers (AC) -- Each receptacle is provided with a "push to reset" circuit breaker to protect the generator against electrical overload.

Electric Start Switch -- Pressed to start the engine.

Grounding Wing Nut -- Use this connection to properly ground the generator.

Idle Control Switch -- The idle control runs the engine at normal (high) speeds when there is a load present and runs the engine at idle (low) speeds when a load is not present.

Recoil Starter = Used as an alternate means of starting the engine.

Run/Stop Switch -- Must be in "Run" position to start engine. Set to "Stop" to stop a running engine.

Spark Arrestor Muffler-- Exhaust muffler lowers engine noise and is equipped with a spark arrestor screen.

/