10000EXL Extended Life Generator

GROUNDING THE

GENERATOR

The National Electrical Code requires that the frame and external electrically conductive parts of this generator be properly connected to an approved earth ground. Local electrical codes may also require additional grounding of the unit. For that purpose, a GROUNDING WING NUT is provided on the generator end (Figure 4).

Figure 4 — Grounding Wing Nut

Grounding

Wing Nut

Generally, connecting a No. 12 AWG (American Wire Gauge) stranded copper wire to the grounding wing nut and to an earth–driven copper or brass grounding rod (electrode) provides adequate protection against electrical shock. Be careful to keep the grounding wire attached after connecting the stranded copper wire. However, local codes may vary widely. Consult with a local electrician for grounding requirements in your area.

Properly grounding the generator helps prevent electrical shock if a ground fault condition exists in the generator or in connected electrical devices, especially when the unit is equipped with a wheel kit. Proper grounding also helps dissipate static electricity, which often builds up in ungrounded devices.

OPERATING THE

GENERATOR

Starting the Engine

Disconnect all electrical loads from the generator. Follow start instruction steps in numerical order:

1.Turn the fuel valve to the “On” position (Figure 5).

Figure 5 — Fuel Shut-off Valve

Fuel Valve is shown

in “On” position

2.Make sure the Idle Control switch is in “Off” position (Figure 6).

Figure 6 — Idle Control Switch

3.Set the Ignition switch to “On(–) position (Figure 7).

Figure 7 — Ignition Switch

4.Pull choke control out to close choke (Figure 8).

Figure 8 — Choke Lever

CAUTION! NEVER start or stop unit with electrical loads connected AND with the connected devices turned ON.

IMPORTANT: Always unplug the battery float charger before starting the generator.