Section 4 – Troubleshooting

Recreational Vehicle Generator

TROUBLESHOOTING GUIDE

Problem

Cause

Correction

The engine will not crank.

1.

Fuse blown

1.

Replace fuse.

 

2.

Loose, corroded or defective

2.

Tighten, clean or replace

 

 

battery cables

 

as necessary.

 

3.

Defective engine Start/Stop

3.

Replace Start/Stop switch.

 

 

switch

 

 

 

4.

Defective starter contactor

4.

Replace contactor.

 

5.

Defective starter motor

5.

Replace starter motor.

 

6.

Low or defective battery

6.

Charge or replace battery.

The engine cranks but

1.

Out of fuel

1.

Replenish fuel.

will not start.

2.

Defective fuel pump

2.

Replace fuel pump.

 

3.

Open #14 wire from

3.

Check connections and.

 

 

engine control board

 

insulation of #14 wires.

 

4.

Flooded engine

4.

Wait 5-10 minutes before trying.

 

5.

Defective spark plug(s)

5.

Clean, re-gap or replace plug(s).

 

6.

Fuel line shut-off closed

6.

Open fuel line shut-off.

 

7.

Plugged fuel filter

7.

Clean or replace fuel filter.

The engine starts hard

1.

Air cleaner

1.

Check, clean or replace air cleaner.

and runs rough.

 

plugged or damaged

 

 

 

2.

Defective spark plug(s)

2.

Clean, re-gap or replace plug(s).

The engine starts, but shuts

1.

Engine oil level low

1.

Check oil and add oil as needed.

down when the Start/Stop

2.

Defective low oil

2.

Replace pressure switch.

switch is released.

 

pressure switch

 

 

 

3.

Defective high temperature

3.

Replace temperature switch.

 

 

switch

 

 

 

4.

Defective engine control board

4.

Replace control board.

 

5.

Overheated engine

5.

Check that the airflow

 

 

 

 

openings are adequate.

The Start/Stop switch is set to Stop, but the engine continues to run.

1.

Defective Start/Stop switch

1.

Replace switch.

2.

Open/Disconnected #18 wire

2.

Reconnect or close wire.

 

between Start/Stop switch

 

 

 

and engine control board

 

 

 

3.

Open/Disconnected #0 wire

3.

Reconnect or close wire.

 

 

between Start/Stop switch

 

 

 

 

and engine control board

 

 

 

4.

Defective engine control board

4.

Replace control board.

There is no AC output from

1.

Main line circuit breaker open

1.

Reset circuit breaker

the generator.

 

 

 

to ON (or closed).

 

2.

Fault with vehicle circuit

2.

Reset and replace if necessary.

 

 

breaker and/or fuses

 

 

3.Transfer switch set to NORMAL

4.Start switch not held long enough to flash the field

3.Set switch to GENERATOR.

4.Stop, then restart the engine (Hold Start switch for at least 2 seconds).

5. Generator internal failure

5. Contact aN Authorized Service

 

Dealer.

35

Page 37
Image 37
Generac Power Systems 004709-0 owner manual Troubleshooting Guide, Problem Cause Correction

004709-0 specifications

Generac Power Systems has established itself as a leader in the home backup generator market with its innovative products, and the Generac 004709-0 is no exception. Designed for homeowners seeking reliable power solutions during outages, this generator ensures peace of mind and uninterrupted operation for essential appliances and electronics.

One of the primary features of the Generac 004709-0 is its robust power output. With a powerful 7,500 running watts and a surge capacity of 9,000 watts, it can efficiently handle large loads, including central air conditioning units, refrigerators, and heat pumps. This generator operates on gasoline, providing an accessible fuel source readily available at most retail locations.

Equipped with a durable 420cc engine, the 004709-0 combines efficiency with exceptional performance. It features a low-oil shutdown system, which safeguards the engine from damage by automatically shutting off when oil levels become critically low. This feature ensures longevity and reliability, making it a dependable choice for homeowners.

The portability of the Generac 004709-0 is another notable characteristic. Weighing approximately 130 pounds, it comes with a built-in handle and sturdy wheels for easy transportation. This feature allows users to move the generator effortlessly from storage to the desired location, which is especially convenient during an emergency.

In addition to power and portability, the Generac 004709-0 boasts user-friendly controls. The control panel includes four 120V household outlets, a 12V automotive outlet, and a circuit breaker, offering flexibility for various connections. Furthermore, the generator is equipped with an easy-to-read fuel gauge and a low-fuel warning light, enhancing operational visibility.

Safety is also paramount in the design of this generator. It includes a powerful muffler that significantly reduces noise and meets stringent regulations for operation in residential areas. Additionally, the 004709-0 incorporates advanced technologies like the PowerDial which allows users to select the correct power level needed for various tasks easily.

Overall, the Generac Power Systems 004709-0 stands out due to its powerful output, user-friendly design, and safety features. Homeowners can rely on this generator to keep their homes powered during outages, ensuring comfort and security for themselves and their families. With its combination of innovation and practicality, the 004709-0 continues to exemplify Generac's commitment to quality and excellence in power solutions.