Section 4 — Maintenance

Guardian Liquid-cooled 27 kW and 30 kW Generators

Do not use any jumper cables or booster bat- ! tery to crank and start the generator engine. If

the battery has completely discharged, remove it from the generator for recharging.

 

PERIODIC REPLACEMENT PARTS

Part Name

 

Generac’s Part Number

Oil Filter

 

# 0E7180

Radiator Cap

 

# 046627

Air Cleaner

 

# 0C8127

Spark Plug

 

# 0E7079

Be sure the AUTO/OFF/MANUAL switch is set to ! the OFF position before connecting the battery cables. If the switch is set to AUTO or MANUAL,

the generator can crank and start as soon as the battery cables are connected.

Be sure the UTILITY power supply is turned off, or sparking may occur at the battery posts as the cables are attached and cause an explosion.

‹4.6.4 BATTERY REPLACEMENT

When replacing batteries, use the same number and the type of battery that follows:

 

BCI Group No.

CCA

 

 

26/26R

525 @ 0 deg. F

 

 

27

600 @ 0 deg. F

 

 

 

 

 

NOTE:

The BCI number should be located directly on the battery.

Generac® Power Systems, Inc. 19

Page 21
Image 21
Generac Power Systems 004988-2 owner manual ‹ 4.6.4 Battery Replacement, Periodic Replacement Parts