Section 6 — Electrical Data

Guardian Air-cooled 7 kW, 12 kW and 15 kW Generators

Electrical Schematic – 12 & 15 kW – Drawing No. 0D8501-B

 

 

 

11

 

 

 

 

 

 

 

 

 

 

 

22

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

225A

 

 

 

 

225A

 

 

 

 

 

 

2

 

 

 

224A

 

 

 

 

 

1

BATTERY

225B

 

 

 

 

F2

224A

 

 

 

 

 

 

 

225

 

 

 

CHARGER

224B

 

 

 

13A

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13A

 

2

 

 

 

 

 

224

 

 

 

 

 

 

 

 

F1

 

 

 

 

1

7

7

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BCR

 

 

11

0

 

 

 

 

6

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13A

 

 

 

 

 

 

 

 

 

 

 

 

 

77

 

 

 

 

 

77

C2-1

BATTERY CHARGE

66

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

WINDING

 

 

 

 

 

 

 

 

66

 

 

 

 

 

 

 

 

 

 

 

 

22

 

 

 

0

C2-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C2-4

 

HTO 0 0

 

 

 

C2-11

 

0

55

 

 

 

 

 

11

BA

 

 

ENGINE RUN

 

SW2

 

 

 

 

 

C1-4

 

 

 

 

0

WINDING

 

 

 

 

 

 

 

 

22

FIELD

 

(STATOR)

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

C2-3

 

 

ELECTRONIC

4

C2-10

 

 

C2-9

 

 

 

 

 

 

 

VOLTAGE

0

4

 

 

 

4

 

 

REGULATOR

0

 

 

 

 

66A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

162

 

 

C1-6

 

 

 

 

 

CB2

 

6

0

 

351

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C2-8

C2-7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

13

0

14

15

 

 

 

0

 

 

0

 

 

 

LOP

 

 

 

14

15

 

 

 

 

C1-3

 

 

 

 

23

 

 

86

194

 

4

22514

224

66A

(STATOR)

DIAGRAM KEY

BA - BRUSH ASSEMBLY

BCR - BATTERY CHARGE RELAY

CB1 - CIRCUIT BREAKER, MAIN OUTPUT CB2 - CIRCUIT BREAKER, ALT. EXCITATION D - DIODE

FS - FUEL SOLENOID F1 - FUSE 15 AMP F2 - FUSE 5 AMP

HTO - HIGH OIL TEMPERATURE SWITCH

IM1 - IGNITION MODULE, CYLINDER #1

IM2 - IGNITION MODULE, CYLINDER #2 LOP - LOW OIL PRESSURE SWITCH SC - STARTER CONTACTER

SCR - STARTER CONTACTOR RELAY SP1, SP2 - SPARK PLUGS

SW1 - AUTO / OFF / MANUAL SWITCH SW2 - SET EXERCISE SWITCH

SM - STARTER MOTOR

TX - TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA (DUAL SEC.)

1 2 3 4 5

J2

CONTROL

PRINTED CIRCUIT BOARD

15A

 

1

23

 

239

J1

4

194

66A

2

86

 

 

 

3

23

 

 

194

5 56 18 7 14

66A

9 239

1015A

17

1215

0

14225

224

16

17

26 Generac® Power Systems, Inc.

Page 28
Image 28
Generac Power Systems 04389-2, 04456-2, 04390-2 owner manual Battery