9) Reinstall the Spider Stopper Guards. Slightly  | Crossover® Ignition System Operations | 
rotate the Spider Stopper Guards so that the  | If the Crossover Ignition System fails to ignite the Left  | 
seams are in line with the Venturi fins(1). There  | burner, light the Left burner with a match. If the Left  | 
should be no gaps in the seams or in the fit around  | burner lights with a match, then check the Crossover  | 
the burners(2) and valves(3).  | Ignition System.  | 
  | ■ Check that both the white(1) and black(2) ignition  | 
  | wires are attached properly.  | 
(1)  | 
  | 
  | |
(3)  | 
  | 
  | |
(2)  | (1)  | (2)  | |
m CAUTION: If the Spider Stopper Guards do not  | 
  | 
  | |
fit tightly, contact the Customer Service Represen-  | ■ Check that the Crossover Ignition button pushes the  | ||
tative in your region using the contact information  | |||
igniter (button) down, and returns to the up position.  | |||
sheet provided with your manual. | |||
■ Check to see if the igniter is loose in the frame.  | |||
m WARNING: After reinstalling the gas lines, they  | |||
Tighten if necessary; See Step “Install igniter” for  | |||
should be leak checked with a soap and water  | |||
correct procedure.  | 
  | ||
solution before using the barbecue. (See Step:  | 
  | ||
If the Crossover Ignition System still fails to light,  | |||
“Check for gas leaks.”) | |||
Contact the Customer Service Representative in your  | |||
  | |||
  | region using the contact information sheet provided  | ||
  | with your manual.  | 
  | |