General Troubleshooting (Always Check the Status LED Light)

Problem

 

 

What To Do

Opener does not run

 

1. Check power source.

from Remote Control

 

A. If Opener is connected to an outlet :

 

 

Plug a working lamp into outlet used for Power Head.

 

 

If lamp glows, power source and outlet are OK.

 

 

If not, check fuse or circuit breaker or non-compatible GFCI.

 

 

NOTE: A licensed electrician must replace non-compatible GFCI’s.

 

 

B. If Opener is connected to a wiring box:

 

 

Check that fuse is not blown, or circuit breaker is on and not tripped or off..

 

 

If still no power, have a licensed electrician check circuit and wiring.

 

 

2. If Power Source is OK :

 

 

Check Power Head Terminal connections (Wall Console Installation on Assembly & Installation Poster), tighten if loose..

 

 

Check connections at Wall Console Terminals, tighten any loose connections..

 

 

Have a Genie Factory Authorized Dealer check that Ribbon Cable between Controller Board and Motor Drive

 

 

Board is properly connected to Connectors on Circuit Boards, or call Customer Service at 1-800-35-GENIE..

 

 

 

 

Door Opener starts

 

Check Wires to ensure that they are not cut (Stapes can cut insulation and short Wires).

for no apparent reason

 

 

Replace any shorting Staples and shorted Wires.

 

 

Was Remote Control lost or stolen? If so, erase all Remote Control codes from Receiver’s memory

 

 

 

and reprogram for remaining remote controls.. (See Erase All Receiver Memory on page 8)..

 

 

Ensure that no Buttons are stuck “pushed-in” on Wall Console or any Remote Controls..

Door starts down, then

 

Check Close Limit Switch setting (see Set Limit Switches and Force Controls on page 7).

stops before it is

 

 

Adjust as needed.

completely closed

 

Check for shorted Wires.

 

 

Check garage door for binding..

Door starts down, then

 

If a new installation, check Door Arm position.

stops and goes back up

 

Check operation of Contact Reverse function.

 

 

Check Safe-T-Beam® System for beam obstruction or misalignment of Lenses.

 

 

Check Safe-T-Beam® System diagnostic code.

 

 

Check Close Force adjustment (see Set Limit Switches and Force Controls on page 7).. Adjust as needed.

 

 

Check garage door for binding..

Door will only run closed

 

Check Open Limit Switch for a short circuit and for proper wiring.

 

 

Check Open Force adjustment (see Set Limit Switches and Force Controls on page 7).. Adjust as needed.

 

 

Check condition of garage door and door spring(s).

 

 

WARNING: If you suspect a problem with the garage door hardware or springs, contact a Genie

 

 

 

Factory Authorized Dealer for service, or contact Customer Service at 1-800-35-GENIE..

 

 

 

 

Door will only run open

 

Check Safe-T-Beam® System as detailed in the Safe-T-Beam® System Self-diagnostic Troubleshooting Chart

 

 

 

(see Safe-T-Beam® System Self-diagnostic Troubleshooting Section on page 13)..

 

 

Check Close Limit Switch for a short circuit and for proper wiring.

 

 

Check Close Force adjustment (see Set Limit Switches and Force Controls on page 7).. Adjust as needed..

Lights will not go out

 

Disconnect Wires connected to Wall Console.. (Wall Console Installation on Assembly & Installation Poster)..

 

 

 

Check their condition and either replace or reconnect..

 

 

Until a replacement Wall Console can be obtained, disconnect Wall Console and use only Remote Controls

 

 

 

or Wireless Keypad to operate Opener.

 

 

 

 

Door starts up, but stops

 

Check (ensure) that garage door and Opener are in good repair, properly lubricated, and properly

before it is

 

 

balanced as detailed in Maintenance Section.

completely open

 

WARNING: If you suspect a problem with the garage door hardware or springs, contact a Genie

 

 

 

Factory Authorized Dealer for service, or contact Customer Service at 1-800-35-GENIE..

 

 

Check Open Limit Switch for a short circuit and for proper wiring.

 

 

Check Open Force adjustment (see Set Limit Switches and Force Controls on page 7).. Adjust as needed..

Operator runs, but door

 

Ensure Magnetic Carriage Assembly is engaged to Rail Drive Screw (see Install Magnetic Carriage Assembly

does not move

 

 

onto Rails on page 10).

 

 

Check Force adjustment (see Set Limit Switches and Force Controls on page 7).. Adjust as needed.

 

 

Check that all sections of Rail Drive Screw are turning when Motor runs.. If not:

 

 

 

– Check condition (not cracked, split, or broken) and placement of Coupler.. Replace as needed.

 

 

 

– Check condition (not cracked, split, or broken) and placement of Collar and Clip.. Replace them

 

 

 

as needed..

 

 

 

 

Wall Console Vacation

 

Ensure Magnetic Carriage Assembly is in contact with Close Limit Switch.

Lock function does

 

Check when door is fully closed, that Carriage activates Close Limit Switch.. If not, adjust position of Close

not work

 

 

Limit Switch (See page 7).

 

 

 

 

continued on next page

12

For Help, call 1-800-35-GENIE or visit www.geniecompany.com

Page 12
Image 12
Genie 3630436275 warranty General Troubleshooting Always Check the Status LED Light, Problem What To Do

3630436275 specifications

The Genie 3630436275 is an innovative piece of equipment that exemplifies cutting-edge technology in the field of aerial work platforms. Engineered with the latest advancements, this versatile lift offers the perfect solution for various construction and maintenance tasks, enabling operators to work safely and efficiently at significant heights.

One of the standout features of the Genie 3630436275 is its impressive working height. With the ability to reach heights that facilitate work on large buildings, infrastructure, and even indoor projects, this lift ensures that users can access challenging spots without compromising safety. The model's compact design allows it to navigate through tight spaces often found in urban construction zones, making it especially suitable for indoor applications as well.

The Genie 3630436275 is equipped with advanced hydraulic systems that provide smooth and responsive lift operation. These mechanisms enable quick ascent and descent, greatly reducing downtime during projects. Additionally, its robust construction guarantees durability and reliability, enabling it to withstand the rigors of continuous use in various environments.

Safety is paramount when it comes to aerial work platforms, and the Genie 3630436275 does not disappoint in this regard. It features multiple safety mechanisms, such as a sturdy guardrail system, emergency stop buttons, and load sensors that ensure operators are working within safe limits. The platform is designed with non-slip surfaces, enhancing grip and stability while working at height.

The technology incorporated into the Genie 3630436275 also includes an intuitive control system that provides operators with precise handling capabilities. The user-friendly interface allows for straightforward control, whether navigating through a job site or setting the lift to the desired height.

Battery-powered options for the Genie 3630436275 further complement its environmentally friendly profile. With quieter operation compared to traditional fuel-powered lifts, it is well-suited for use in noise-sensitive areas or during off-hours work.

In conclusion, the Genie 3630436275 is a versatile, high-performing aerial lift that combines innovative technology, durable construction, and an emphasis on safety. With its array of features, it serves as an essential tool for professionals across various industries, streamlining access to elevated work areas while prioritizing user safety and convenience. This model is an excellent choice for those seeking reliability and efficiency in their aerial work platform solutions.