Normal operating characteristics.

GEAppliances.com

7KHVHWKLQJVDUHQRUPDODQG

 

 

GRQRWLQGLFDWHDQHHGIRUVHUYLFH

 

 

„ A warm cabinet exterior as the refrigeration system transfers

„ The sound of the high-efficiency compressor motor.

heat from the inside to the outside through the exterior

 

 

cabinet walls.

 

 

Before you call for service…

7URXEOHVKRRWLQJ7LSV

6DYHWLPHDQGPRQH\5HYLHZWKHFKDUWVRQWKHIROORZLQJ SDJHVILUVWDQG\RXPD\QRWQHHGWRFDOOIRUVHUYLFH

 

Problem

 

Possible Causes

What To Do

 

 

 

 

 

 

Freezer does not

 

Temperature control

• Move the control to a temperature setting.

 

operate or Power-On

 

in OFF position.

 

 

Light is not on

 

 

 

 

 

Freezer is unplugged.

• Push the plug completely into the outlet.

 

 

 

 

 

 

 

 

 

 

 

The fuse is blown/circuit

• Replace fuse or reset the breaker.

 

 

 

breaker is tripped.

 

 

 

 

 

 

 

Freezer starts/stops

 

Door/lid left open.

• Check to see if package is holding door/lid open.

 

too frequently

 

 

 

 

 

Too frequent or too long

 

 

 

 

 

 

 

 

door/lid openings.

 

 

 

 

 

 

 

 

 

Temperature control

• See $ERXWWKHRSHUDWLRQRI\RXUIUHH]HU

 

 

 

set too cold.

 

 

 

 

 

 

 

Freezer operates

 

Door/lid left open.

• Check to see if package is holding door/lid open.

 

too long

 

 

 

 

 

Too frequent or too long

 

 

 

 

 

 

 

 

door/lid openings.

 

 

 

 

 

 

 

 

 

Temperature control

• See $ERXWWKHRSHUDWLRQRI\RXUIUHH]HU

 

 

 

set too cold.

 

 

 

 

 

 

 



 

Inadequate air circulation

• See 3UHSDULQJWRLQVWDOOWKHIUHH]HU

 

 

 

space around cabinet.

 

 

 

 

 

 

 

 

 

Fast Freeze switch is in the

• See $ERXWWKHRSHUDWLRQRI\RXUIUHH]HU

 



 

ON position (on some models).

 

 

 

 

 

 

 

Noisy operation

 

Floor may be weak, causing

• Placing 2 X 4’s (51 mm X 102 mm) under the length of

 

or cabinet vibrates

 

freezer to vibrate when

the freezer will help support it and may reduce vibration.

 

 

 

compressor is on.

 

 

 

 

 

 

 

 

 

Cabinet is not positioned

• See 3UHSDULQJWRLQVWDOOWKHIUHH]HUOr use shims for

 



 

solidly on floor.

 uneven floor.

 

 

 

 

 

 

Freezer temperature

 

Door/lid left open.

• Check to see if package is holding door/lid open.

 

too warm

 

 

 

 

 

Too frequent or too long

 

 

 

 

 

 

 

 

door/lid openings.

 

 

 

 

 

 

9

Page 9
Image 9
Genie FCM7, FCM11, FCM5 owner manual Before you call for service…, „ The sound of the high-efficiency compressor motor

FCM5, FCM11, FCM7 specifications

The Genie FCM7, FCM11, and FCM5 are advanced mobile elevating work platforms (MEWPs) designed for a variety of tasks in the construction, maintenance, and industrial sectors. These models combine cutting-edge technology with user-friendly features to enhance productivity and safety on the job site.

The Genie FCM7 is characterized by its compact design, making it ideal for tasks in confined spaces. It boasts a maximum working height of approximately 7.5 meters, allowing operators to efficiently access elevated areas. The FCM7 is powered by a robust electric motor, providing quiet operation with zero emissions, which is essential for indoor use. The unit features a simplified control system for easy maneuverability and has a weight capacity of up to 227 kg, accommodating both personnel and tools.

The Genie FCM11 takes things a step further with a maximum working height of around 11 meters. This model is particularly popular for applications requiring greater reach without compromising stability. It offers advanced safety features such as tilt sensors, which enhance operator confidence when working on uneven surfaces. The FCM11 also includes a spacious platform that can hold up to two workers, making it suitable for more complex tasks that necessitate teamwork.

On the other hand, the Genie FCM5 is the entry-level model in this lineup, with a maximum working height of roughly 5.2 meters. Its lightweight design is perfect for light-duty applications, and it is an excellent choice for smaller job sites with limited access. The FCM5 is also equipped with a user-friendly control panel, ensuring operators can navigate the equipment with ease. Its compact design allows for easy transportation, making it a versatile solution for various projects.

All three models share several common features, including durable construction, onboard diagnostics for maintenance efficiency, and energy-saving modes that extend battery life. Additionally, these units are designed with rigorous safety standards, including emergency stop buttons and stable outriggers for added support. With their emphasis on innovation and ergonomics, the Genie FCM series represents a reliable choice for contractors and workers looking to enhance their operational efficiency while prioritizing safety in the workplace.