| Specifications |
Volume | Model GP5132 |
Up to 29 GPM | |
Discharge Pressure | Up to 3000 PSI |
Speed | Up to 1000 RPM |
Inlet Pressure | Up to 145 PSI |
Plunger Diameter | 32 mm |
Plunger Stroke | 46mm |
Crankshaft Diameter | 35mm x 10mm key |
Crankshaft Mounting | Either side |
Shaft Rotation | Top of pulley towards manifold |
Temperature of Pumped Fluids | Up to 140 oF |
Inlet Ports | (3) |
Discharge Ports | (2) 1" BSP |
Weight | 179 lbs. |
Crankcase Oil Capacity | 1.2 Gal. |
Fluid End Material | Cast Iron |
Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above.
GP5132 HORSEPOWER
REQUIREMENTS
RPM | GPM | 1OOO | 15OO | 2OOO | 25OO | 3000 | |
PSI | PSI | PSI | PSI | PSI | |||
|
| ||||||
|
|
|
|
|
|
| |
600 | 17.4 | 12 | 18 | 24 | 30 | 36 | |
|
|
|
|
|
|
| |
700 | 20.3 | 14 | 21 | 28 | 35 | 42 | |
|
|
|
|
|
|
| |
900 | 26.1 | 18 | 27 | 36 | 45 | 54 | |
|
|
|
|
|
|
| |
1000 | 29 | 20 | 30 | 40 | 50 | 60 | |
|
|
|
|
|
|
|
SPECIAL NOTE:
FOR CONTINUAL OPERATION, THE SPEED OF THE PUMP MUST BE LIMITED TO 700 RPM, AND THE MAXIMUM PRESSURE OF THE PUMP MUST BE REDUCED BY 10%.
HORSEPOWER RATINGS: The rating shown are the power
requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above.
We recommend a 1.15 service factor be specified when selecting an electric motor as the power source. To compute specific pump horse- power requirements, use the follow- ing formula:
HP = (GPM X PSI) / 1450
3